Защищенный по военным стандартам ноутбук Bit-RPC 1522D-MIL предназначен для тяжелых промышленных или полевых задач, требующих предельной живучести и надежности при достаточной портативности и мобильности в условиях близких к экстремальным.
Features:
Computer System
|
|
Backplane System
|
PICMG 1.0 with 6x free PCI Full Size Slots and 1x CPU Slot
|
CPU Card
|
PICMG Core2Duo CPU Card with Intel 945 GME Chipset
|
CPU
|
Intel Core2Duo T7400 (2.16 GHz)
|
Memory
|
2GByte DDR2 Standard, optional up to 4 GByte
|
Grafik Controller
|
Integrated in Chipset with LVDS Interface for internal Display and VGA Port
|
|
|
HDD
|
Removable 2.5” 80GByte SATA automotive drive behind Service Door
|
Optical Drive
|
Slimline SATA DVD Writer with Tray behind Service Door
|
|
|
Size
|
381mm / 15,0” Industrial Grade TFT
|
Resolution
|
1024 x 768 pxs native XGA resolution with 16M colours
|
Viewing Area
|
381mm diagonal active view area (304.1mm x 228.1mm) (~15.0”)
|
Aspect Ratio
|
4:3 aspect ratio
|
Pixel Size
|
0,297mm pixel pitch
|
Viewing Angle
|
-75° ~ 75° typ. (H), typ. -60° ~ 50° (V)
|
Backlight
|
250 cd/mІ backlight with 2 CCFL tubes, replaceable
|
|
|
Ethernet
|
2x Gigabit Ethernet behind Service Door
|
USB
|
1x USB 2.0 behind Service Door, 4x USB 2.0 on CPU Board (ICD)
|
Serial Port
|
1x RS232 (COM2) behind Service Door
|
Parallel Port
|
1x IEEE1284 on CPU Board (ICD)
|
External Display
|
1x VGA behind Service Door on HD-SUB15
|
Connector Side Box
|
The unit comes with blank connector side box per default. Customers may mill their own breakthroughs for additional connectors. As alternative, customer may provide a connector list and the unit will be delivered with pre milled connector side box. Please consult factory for this option.
|
|
|
Supply Voltage DC
|
10V-32V DC input on IP65 Round Connector
|
Supply Voltage AC
|
90V-240V with 45Hz-400Hz on IP65 Round Connector
|
UPS (as Option)
|
Integrated UPS with Battery for approx. 10~15min. Runtime
|
UPS Monitoring
|
Monitoring with Serial Interface (COM1) with legacy driver in Windows XP pro
|
|
|
Material
|
Precision milled aluminum enclosure
|
Coating / Painting
|
Surtec 650 surface treatment, Olive powder coating
|
Outside Dimensions
|
(H)198mm x (W)491mm x (D)474mm outside dimension
|
TFT Protection
|
Hardened non-reflecting protection glass
|
Special Features
|
Drives behind Service Door, Front sided fully environmental sealed Heat Exchanger
|
Weight
|
Approx. 20 kg
|
|
|
Temperature
|
MIL-STD 810F Method 501.4, Proc I (71°C) & II (50°C) (High Temp)
MIL-STD 810F Method 502.4, Proc I (-40°C) & II (-20°C) (Low Temp) MIL-STD 810F Method 503.4, -40° to 71°C non-operating |
Humidity
|
MIL-STD-810F Method 507.4, 5 cycles б 48h each at +30°C…+60°C at 95% rh
|
Operating Altitude
|
MIL-STD 810F Method 500.4 Proc I 15 kft & Proc II 10 kft
|
Fungus
|
MIL-STD 810F Method 508.5, Aspergillus niger, Aspergillus flavus, Aspergillus versicolor, Penicillium funiculosum, Chaetomium globosum
|
Contamination
|
MIL-STD 810F Method 504, Fuels (F-34), Hydraulic Oil (MIL-H-5606), Lubricant Oil (O-156), Coolant dielectric fluid (S-1748)
|
Vibration
|
MIL-STD 801F Method 514.5, Proc I (max. 2g RMS)
|
Shock
|
MIL-STD 810F Method 516.5, Proc I, Proc IV, Proc IV
|
Saltfog
|
MIL-STD 810F Method 509.4
|
Rain
|
MIL-STD 810F Method 506.4
|
IP Protection
|
IP65 (DIN EN 60259 / IEC 529) / NEMA4
|
|
|
Conducted Emissions / CE
|
CE-EFA-1 Power Leads, 20Hz…100MHz (similar to MIL461E CE101 & CE102)
CE-EFA-2 Control and Signal Leads,20Hz…100MHz (similar to MIL461E CE101 & CE102) CE-EFA-3 Power Leads, Exported Transients |
Radiated Emissions / RE
|
RE-EFA-1 Electric Field, 50kHz…40GHz (similar MIL461E RE102)
|
Conducted Susceptibility / CS
|
CS-EFA-1 Power Leads, 20Hz…50kHz (similar MIL461E CS101)
CS-EFA-AGE-2 Power & Signal Leads, 50kHz…400MHz (Bulk Current Injection Method) (similar MIL461E CS114) CS-EFA-4 Power Leads, Imported Spikes & Transients |
Radiated Susceptibility / RS
|
RS-EFA-AGE-3 50kHz…18GHz (similar MIL461E RS101 & RS103)
|
Electrostatic Discharge / ESD
|
ESD-EFA-1
- 150pF / 330O, Air Discharge - 4 kV, 6 kV, 8 kV, 10 kV and 12 kV on 7 test points - 5 pulses shall be applied with a minimum period between the pulses of 10 seconds - Positive and Negative Polarity |