System | |
Процессор | 16-bit CPU |
SRAM | 512 KB |
Flash Memory | 512 KB |
EEPROM | 16 KB |
Сторожевой таймер | Да (0.8 секунд) |
NVRAM | 31 Bytes |
ОС | MiniOS7 |
Часы реального времени | RTC поддерживают секунды, минуты, часы, недели, месяцы, года, в промежутке с 1980 по 2079 |
64-бит ключ | Да |
Интерфейсы | |
PoE Ethernet Port | RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) |
COM 1 | No (Unsupported by WISE firmware) |
COM 2 | No (Unsupported by WISE firmware) |
FRnet | Max. 1 M |
LED Indicators | |
System LED | Yes (Red) |
Светодиодный LED-экран | 5-digit 7-segment Светодиодный LED-экран |
Special Indicator | PoE LED (Green) |
Power Requirements | |
Reserve Polarity Protection | Да |
Powered from PoE | Yes, IEEE 802.3af, Class 1 |
Consumption | 2.5 W |
Frame Ground | Yes (for ESD Protection) |
Input Range | +12 ~ +48 VDC |
Mechanical | |
Габариты (Ш x В x Г) | 72 mm x 123 mm x 35 mm |
Installation | DIN-Rail or Wall mounting |
Environment | |
Рабочая температура | -25 °C ~ +75 °C |
Допустимая температура в режиме хранения | -40 ~ +80 °C |
Влажность | 5 ~ 90% RH, non-condensing |
Functions | |
Rule Configuration Website | Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules | 3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions |
48 Internal Registers | Hold temporary variables and read/write data via Modbus/TCP address. |
12 Timers | Delay / Timing functions |
12 Schedules | Setup prescheduled routine tasks. |
12 Emails | Send Email messages to pre-set Email receivers. |
12 CGI Commands | Send pre-set CGI commands. |
12 Recipes | Set up THEN/ELSE action groups. |
8 P2P remote modules | Set up the connection information for the remote WISE modules. |
Modbus/TCP Protocol | Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
IF Conditions | |
DI Channel | ON, OFF, ON to OFF, OFF to ON, Change |
Internal Register | =, and lt , and gt , and gt =, and lt = (value) |
DI Counter | =, and gt , and lt , and gt =, and lt =(value), Change |
DO Counter | =, and gt , and lt , and gt =, and lt =(value), Change |
Timer | Timeout, Not Timeout |
Schedule | In Range, Out of Range |
P2P | DI, AI, DI counter, DO counter, IR |
Rule Status | Enable, Disable |
THEN / ELSE Actions | |
DO Channel | ON, OFF, Pulse Output |
Internal Register | Change the value |
DI Counter | Reset |
DO Counter | Reset |
Timer | Start, Stop |
Schedule | Start, Stop |
Send | |
CGI Commands | Send |
Recipe | Execute |
P2P | DO(On/Off), AO, IR |
Rule Status | Enable, Disable |