WISE-5800

WISE-5800
Артикул: WISE-5800
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
User-defined I/O and Data Logger Module

Подробные технические характеристики (спецификация)

System
Процессор16-bit CPU
SRAM768 KB
Flash Memory512 KB
EEPROM16 KB
Сторожевой таймерДа (0.8 секунд)
NVRAM31 Bytes
Часы реального времениRTC Provide seconds, minutes, hours, date of week/month month and year
microSDYes, can support 1 or 2 GB microSD
Интерфейсы
PoE Ethernet PortRJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
COM 1RS-232 (Reserved, Unsupported by WISE firmware)
COM 2RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max.
LED Indicators
System LEDYes (Red)
Светодиодный LED-экран-
Ethernet Link LEDYes (Green : Ethernet link detected, Flashing Green : Ethernet packet received)
Hardware Expansion
I/O Expansion BusДа
Power Requirements
Reserve Polarity ProtectionДа
Consumption2.0 W
Frame GroundYes (for ESD Protection)
Input Range+12 ~ +48 VDC
Redundant Power InputДа
Mechanical
Габариты (Ш x В x Г)91 mm x 123 mm x 52 mm
InstallationDIN-Rail
Environment
Рабочая температура-25 °C ~ +75 °C
Допустимая температура в режиме хранения-30 °C ~ +80 °C
Влажность10 ~ 90% RH, non-condensing
Functions
Rule Configuration WebsiteAccess Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions
48 Internal RegistersHold temporary variables and read/write data via Modbus/TCP address.
12 TimersDelay / Timing functions
12 SchedulesSetup prescheduled routine tasks.
12 EmailsSend Email messages to pre-set Email receivers.
12 CGI CommandsSend pre-set CGI commands.
12 RecipesSet up THEN/ELSE action groups.
Modbus/TCP ProtocolReal time control and monitoring I/O channels and system status of controllers via SCADA software.
Data LoggerSet up the Data Logger configuration, include the data record format, and data file sending operation.
IF Conditions
DI ChannelON, OFF, ON to OFF, OFF to ON, Change
AI Channel=, and lt , and gt , and gt =, and lt = (value)
Internal Register=, and lt , and gt , and gt =, and lt = (value)
DI Counter=, and gt , and lt , and gt =, and lt =(value), Change
TimerTimeout, Not Timeout
ScheduleIn Range, Out of Range
Rule StatusEnable, Disable
THEN / ELSE Actions
DO ChannelON, OFF, Pulse Output
AO ChannelChange the value
Internal RegisterChange the value
DI CounterReset
TimerStart, Stop
ScheduleStart, Stop
EmailSend
CGI CommandsSend
RecipeExecute
Rule StatusEnable, Disable
Data LoggerStart, Stop, One-Time Log
Нет отзывов об этом товаре.

Написать отзыв о WISE-5800

Ваше Имя:


Ваш отзыв:

Оценка: Плохо           Хорошо

Введите код, указанный на картинке: