Ничего не куплено!
Продажа и внедрение оборудования для промышленной автоматизации
Mail: prom@protonpc.ru
Тел: (495) 789-41-64 доб. 303
Описание | ||
24 V DC | ||
Основные характеристики | ||
Signal type | Digital Input | |
Supply | ||
Подключение | terminals 23+, 24- or power feed module/Power Rail | |
Rated voltage | 20 ... 30 V DC | |
Rated current | приблизительно 130 mA | |
Power loss | 2.2 W | |
Потребляемая мощность | 2.5 W | |
Вход | ||
Подключение | input I: terminals 1+, 3- input II: terminals 4+, 6- input III: terminals 13+, 14- (control input 1) input IV: terminals 15+, 14- (control input 2) | |
Input I, II | 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact | |
Open circuit voltage/short-circuit current | 8.2 V / 10 mA | |
Pulse duration | min. 250 µ-s , overlap on direction of rotation signal: &ge- 125 µ-s | |
Input frequency | rotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz | |
Lead monitoring | breakage I &le- 0.15 mA- short-circuit I > 6.5 mA | |
Input III, IV | ||
Active/Passive | I > 4 mA (for min. 100 ms) / I < 1.5 mA | |
Open circuit voltage/short-circuit current | 18 V / 5 mA | |
Выход | ||
Подключение | output I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 19+, 20- output IV: terminals 21+, 20- output V: terminals 7-, 8+ | |
Output I, II | signal , relay | |
Contact loading | 250 V AC / 2 A / cos &phi- &ge- 0.7 - 40 V DC / 2 A | |
Mechanical life | 5 x 107 switching cycles | |
Energized/De-energized delay | приблизительно 20 ms / приблизительно 20 ms | |
Output III and IV | signal , electronic output, passive | |
Contact loading | 40 V DC | |
Signal level | 1-signal: (external voltage) - 2.5 V max. for 10 mA or 3 V max. for 100 mA (100 mA, short-circuit proof) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: switched off (off-state current &le- 10 µ-A) | |
Output V | analog | |
Current range | 0 ... 20 mA or 4 ... 20 mA | |
Open loop voltage | max. 24 V DC | |
Load | max. 650 &Omega- | |
Fault signal | downscale I &le- 3.6 mA, upscale I &ge- 21.5 mA (acc. NAMUR NE43) | |
Programming interface | ||
Connection | programming socket | |
Интерфейс | RS 232 | |
Collective error message | Power Rail | |
Transfer characteristics | ||
Input I and II | ||
Measurement range | 0.001 ... 1000 Hz | |
Разрешение | slip monitoring: 1% frequency measurement: 0,1% of measured value- but >0.001Hz | |
Accuracy | slip monitoring: 1% frequency measurement: 0.5% of measured value- but >0.001Hz | |
Measuring time | frequency measurement: < 100 ms | |
Influence of ambient temperature | 0.003 %/K (30 ppm) | |
Соответствие директивам | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61326-1:2006 | |
Low voltage | ||
Directive 2006/95/EC | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Стандарты защищенности | IEC 60529:2001 | |
Условия окружающей среды | ||
Рабочая температура окружающей среды | -20 ... 60 °C (-4 ... 140 °F) | |
Физические/механические параметры | ||
Стандарты защищенности | IP20 | |
Масса | 300 g | |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 in) , housing type C3 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with Ex-areas | ||
EC-Type Examination Certificate | TUV 99 ATEX 1471 , for additional certificates see www.pepperl-fuchs.com | |
Group, category, type of protection | II (1)GD, I (M1) [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C &le- Tamb &le- 60 °C) | |
Statement of conformity | TUV 02 ATEX 1885 X | |
Group, category, type of protection, temperature class | II 3G Ex nA nC IIC T4 | |
Output I, II | ||
Contact loading | 50 V AC/2 A/cos &phi- > 0.7- 40 V DC/1 A resistive load | |
Соответствие директивам | ||
Directive 94/9/EC | EN 60079-0:2009, EN 60079-11:2007 , EN 60079-15:2005 , EN 60079-26:2007 , EN 61241-11:2006 | |
International Сертификаты | ||
FM approval | ||
Control drawing | 16-538FM-12 |