Performance |
| Resolution: | , 0.1 mm, 1 mm | |
| Repeatability 1): | 1 mm | |
| Output rate: | 5 ms | |
| Light source: | LED, red | |
| Measurement range 2): | 0 m ... 10,000 m | |
| Service life 3): | 100,000 h | |
| Bar code width 4): | 40 mm | |
| MTTFd: | > 100 years | |
| Sensing distance: | 130 mm, ± 20 mm (to bar code tape, 40 mm bar code width) | |
| Max. movement speed: | 4 m/s | |
Interfaces |
| Data interface: | RS-485 | |
Mechanics/electronics |
| Supply voltage Vs 1): | DC 10 V ... 30 V | |
| Residual ripple 2): | ≤- 5 Vpp | |
| Power consumption: | < 3 W | |
| Initialization time: | < 3 s | |
| Housing material: | Aluminum zinc | |
| Weight: | Ca. 260 g | |
Ambient data |
| Enclosure rating: | IP 65 (EN 60 529) | |
| Protection class: | III | |
| EMC: | EN 61000-6-2 EN 61000-6-4 | |
| Ambient temperature 1) 2): | Operation: -30 ... 60 °C, Storage: -40 ... 75 °C | |
| Typ. ambient light safety 3): | ≤- 30,000 lx | |
| Vibration resistance: | DIN/EN 60068-2-6, DIN/EN 60068-2-64 | |
| Shock resistance: | DIN/EN 60068-2-27 | |
*изображение на сайте может отличаться от реального