Features |
| Version: | Mid Range | |
| Connection type: | Ethernet | |
| Reading field: | Front | |
| Scanner design: | Raster scanner | |
| Focus: | Fixed focus | |
| Light source: | Visible red light (655 nm) | |
| MTBF: | 40,000 h | |
| Laser class: | 2 (EN 60825-1 (A2:2001-03)) | |
| Field of view: | ≤- 50 ° | |
| Scanning frequency: | 400 Hz ... 1,200 Hz | |
| Code resolution: | 0.2 mm ... 1 mm | |
| Reading distance (at code resolution): | 60 mm ... 365 mm (1 mm) | |
| Raster height, number of lines, at distance: | 15 mm, 8, 200 mm | |
Performance |
| Bar code types: | Interleaved 2 of 5, All current code types, Codabar, Code 128, Code 39, Code 93, EAN, EAN 128, GS1 DataBar, Pharmacode, UPC | |
| Print ratio: | 2:1 ... 3:1 | |
| No. of codes per scan: | 1 ... 20 (Standard decoder), 1 ... 6 (SMART620) | |
| No. of codes per reading interval: | 1 ... 50 (auto-discriminating) | |
| No. of characters per reading interval: | 5,000, 500 (for multiplexer function in CAN operation) | |
| No. of multiple readings: | 1 ... 99 | |
Interfaces |
| Serial (RS-232, RS-422/485): | Yes | |
| Remark (Serial (RS-232, RS-422/485)): | AUX (only RS-232) | |
| Function (Serial (RS-232, RS-422/485)): | Host, AUX | |
| Data transmission rate (Serial (RS-232, RS-422/485)): | 2,400 Baud ... 115 Baud , AUX: 57.6 kBaud | |
| Ethernet: | Yes | |
| Function (Ethernet): | Host, AUX | |
| Protocol (Ethernet): | TCP/IP, EtherNet/IP, PROFINET | |
| Data transmission rate (Ethernet): | 10/100 Mbit | |
| CAN bus: | Yes | |
| Function (CAN bus): | SICK CAN sensor network (Master/Slave, Multiplexer/Server) | |
| Protocol (CAN bus): | CANopen®, CSN (SICK CAN Sensor Network) | |
| Data transmission rate (CAN bus): | 20 kbit/s ... 1 Mbit/s | |
| PROFIBUS: | Yes | |
| Remark (PROFIBUS): | Optional via external connection module (CDF) | |
| PROFINET: | - | |
| EtherCAT: | Yes | |
| Remark (EtherCAT): | Optional via external connection module (CDF) | |
| DeviceNet: | Yes | |
| Remark (DeviceNet): | Optional via external connection module (CDM + CMF) | |
| Connector: | Pivotable | |
| Switching inputs: | 3 (“Sensor 1”, 2 inputs via CMC600 in CDB620/CDM420) | |
| Switching outputs: | 2 (via CMC600 in CDB620/CDM420) | |
| Reading pulse: | Auto pulse, Non-powered, Switching inputs, Serial interface | |
| Optical indicators: | 6 LEDs (Ready, Result, Laser, Data, CAN, LNK TX) | |
| Acoustic indicators: | Beeper/buzzer (can be switched off, can be allocated as a result status indication function) | |
Mechanics/electronics |
| Electrical connection: | 2 M12 cylindrical connectors (12-pin plug, 4-pin socket) on swivel connector | |
| Operating voltage: | 10 V DC ... 30 V DC | |
| Power consumption: | 4.5 W | |
| Housing: | Die-cast aluminum | |
| Housing color: | Light blue (RAL 5012) | |
| Enclosure rating: | IP 65 (DIN 40 050) | |
| Protection class: | III (VDE 0106/IEC 1010-1) | |
| Weight: | 205 g, without connecting cable | |
| Dimensions: | 61 mm x 66 mm x 38 mm 1) | |
Ambient data |
| Electromagnetic compatibility (EMC): | EN 61000-6-3 (2001-10) / EN 61000-6-2:2005 | |
| Vibration resistance: | EN 60068-2-6 (1995) | |
| Shock resistance: | EN 60068-2-27 (1993) | |
| Ambient operating temperature: | 0 °C ... 40 °C | |
| Storage temperature: | -20 °C ... 70 °C | |
| Permissible relative humidity: | 90 %, non-condensing | |
| Ambient light safety: | 2,000 lx, on bar code | |
| Bar code print contrast (PCS): | ≥- 60 % | |
*изображение на сайте может отличаться от реального