Bar code scanners
CLV45x / CLV451 / Low Density
 
Model NameCLV451-6010
Part No.1019524
 

Самое главное

  • Dynamic focus control in real time
  • Immune to ambient light
  • Large reading distance of up to 1.6 m
  • Auto setup ensures automatic optimizing of reading performance
  • CAN bus compatible
  • High read rates, even with damaged, rotated, or dirty bar codes
  • Adjustable scanning frequency up to 1,000 scans per second

    Преимущества

  • Reliable bar code identification across large reading distances
  • Dynamic focus control allows the scanner to accommodate a large depth of field by dynamically adjusting the focus to the object distance
  • Small size and simple setup enables fast installation, even in compact machines
  • Extremely easy to configure, shortening commissioning time
  • Short commissioning time
  • Reliable operation
  • Parameter cloning plug ensures very short MTTR
     
     
         

    Note: The product is currently being phased out and can be ordered until September 30, 2013. A replacement product can be found under "Replacement Products"


    Features
    Version:Low Density
    Connection type:Standard
    Reading field:Oscillating mirror
    Scanner design:Line scanner
    Focus:Dynamic focus control
    No. of distance configurations:8
    Focus adjustment time:≤- 50 ms
    Focus trigger source:Switching input "Sensor 2", Serial interface, Timer
    Light source:Visible red light (650 nm)
    MTBF:20,000 h
    Laser class:2 (DIN EN 60825-1)
    Field of view:≤- 50 °
    Scanning frequency:400 Hz ... 1,000 Hz
    Code resolution:0.5 mm ... 0.5 mm
    Reading distance (at code resolution):150 mm ... 780 mm (0.5 mm)
    Oscillating mirror functions:Fixed (adjustable position), One shot, Oscillating (variable or fixed amplitude)
    Oscillation frequency:0.5 Hz ... 4 Hz
    Angle of deflection:-20 ° ... 20 ° (can be adjusted via software)


    Performance
    Bar code types:Interleaved 2 of 5, All current code types, Codabar, Code 128, Code 39, Code 93, EAN, EAN 128, UPC
    Print ratio:2:1 ... 3:1
    No. of codes per scan:1 ... 20 (Standard decoder), 1 ... 6 (SMART decoder)
    No. of codes per reading interval:1 ... 50 (auto-discriminating)
    No. of characters per reading interval:500
    No. of multiple readings:1 ... 99


    Interfaces
    Serial (RS-232, RS-422/485):Yes
    Remark (Serial (RS-232, RS-422/485)):AUX (only RS-232)
    Function (Serial (RS-232, RS-422/485)):Host, AUX
    Data transmission rate (Serial (RS-232, RS-422/485)):300 Baud ... 57,600 Baud , AUX: 9,600 Baud
    Ethernet:Yes
    Remark (Ethernet):Optional via external connection module (CDM + CMF)
    CAN bus:Yes
    Function (CAN bus):SICK CAN sensor network (Master/Slave, Multiplexer)
    Protocol (CAN bus):CANopen®, CSN (SICK CAN Sensor Network)
    Data transmission rate (CAN bus):10 kbit/s ... 1 Mbit/s
    PROFIBUS:Yes
    Remark (PROFIBUS):Optional via external connection module (CDM + CMF)
    PROFINET:-
    DeviceNet:Yes
    Remark (DeviceNet):Optional via external connection module (CDM + CMF)
    Switching inputs:2 (“Sensor 1”, “Sensor 2”)
    Switching outputs:2 (“Result 1”, “Result 2”)
    Reading pulse:Non-powered, "Sensor 1" switching input, Serial interface
    Optical indicators:4 LEDs (function indicator)
    Acoustic indicators:Beeper/buzzer (can be switched off, can be allocated as a result status indication function)


    Mechanics/electronics
    Electrical connection:1 15-pin D-Sub HD plug (0.9 m)
    Operating voltage:10 V DC ... 30 V DC 1)
    Power consumption:7.2 W
    Housing:Die-cast zinc, does not contain paint wetting impairment substances
    Housing color:Light blue (RAL 5012)
    Enclosure rating:IP 65 (DIN 40 050)
    Protection class:III (VDE 0106)
    Weight:700 g, with connecting cable
    Dimensions:99.8 mm x 90 mm x 37.8 mm
    1) UL certified for use with a Class 2 mains supply unit (checked to UL 1310)  


    Ambient data
    Electromagnetic compatibility (EMC):EN 61000-6-4 / EN 61000-6-1 / EN 61000-6-2
    Vibration resistance:IEC 68-2-6 Test FC
    Shock resistance:IEC 68-2-27 Test EA
    Ambient operating temperature:0 °C ... 40 °C
    Storage temperature:-20 °C ... 70 °C
    Permissible relative humidity:± 90 %, non-condensing
    Ambient light safety:2,000 lx, on bar code


    General notes
    Life cycle phase:Available until September 30th, 2013