Features |
| Version: | Standard Density | |
| Connection type: | Standard | |
| Reading field: | Front | |
| Scanner design: | X scanner (2 lines offset from each other at a 90° angle) | |
| Focus: | Auto focus (alternative: dynamic focus control) | |
| No. of distance configurations: | 8 | |
| Focus adjustment time: | ≤- 20 ms | |
| Focus trigger source: | Data interface, Switching inputs "IN 0 ... IN 4", Timer | |
| Light source: | Visible red light (650 nm) | |
| MTBF: | 80,000 h | |
| Laser class: | 2 (DIN EN 60825-1) | |
| Field of view: | ≤- 60 ° | |
| Scanning frequency: | 600 Hz ... 1,200 Hz | |
| Code resolution: | 0.3 mm ... 1 mm | |
| Reading distance (at code resolution): | 500 mm ... 1,750 mm (0.5 mm) | |
| Heating: | Yes | |
| Switch on delay: | 35 ... 40 min at -35 °C and 24 V DC | |
Performance |
| Bar code types: | Interleaved 2 of 5, All current code types, Codabar, Code 128, Code 39, Code 93, EAN, EAN 128, UPC | |
| Print ratio: | 2:1 ... 3:1 | |
| No. of codes per scan: | 1 ... 12 (Standard decoder), 1 ... 6 (SMART decoder) | |
| No. of codes per reading interval: | 1 ... 50 (auto-discriminating) | |
| No. of characters per reading interval: | 600 | |
| No. of multiple readings: | 1 ... 99 | |
Interfaces |
| Serial (RS-232, RS-422/485): | Yes | |
| Remark (Serial (RS-232, RS-422/485)): | AUX (only RS-232) | |
| Function (Serial (RS-232, RS-422/485)): | Host, AUX | |
| Data transmission rate (Serial (RS-232, RS-422/485)): | 300 Baud ... 57,600 Baud , AUX: 9,600 Baud | |
| Ethernet: | Yes | |
| Remark (Ethernet): | Optional via external connection module (CDM + CMF) | |
| CAN bus: | Yes | |
| Function (CAN bus): | SICK CAN sensor network (Master/Slave, Multiplexer) | |
| Protocol (CAN bus): | CANopen®, CSN (SICK CAN Sensor Network) | |
| Data transmission rate (CAN bus): | 10 kbit/s ... 1 Mbit/s | |
| PROFIBUS: | Yes | |
| Remark (PROFIBUS): | Optional via external connection module (CDM + CMF) | |
| PROFINET: | - | |
| DeviceNet: | Yes | |
| Remark (DeviceNet): | Optional via external connection module (CDM + CMF) | |
| Switching inputs: | 6 (Sensor, IN 0 ... IN 4) | |
| Switching outputs: | 4 (“Result 1” ... “Result 4”) | |
| Reading pulse: | Data interface, Non-powered, OTS (Omni tracking), "Sensor 4" switching input (+ "IN 4") | |
| Optical indicators: | 4 LEDs (function indicator) | |
Mechanics/electronics |
| Electrical connection: | 1 x 15-pin D-Sub HD device plug 1 x 15-pin D-Sub HD device socket | |
| Operating voltage: | ≤- 24 V DC± 10 % | |
| Power consumption: | 90 W | |
| Housing: | Die-cast aluminum, no materials containing silicone on outside | |
| Housing color: | Light blue (RAL 5012) | |
| Enclosure rating: | IP 65 (EN 60529 (1991-10)) | |
| Protection class: | III (EN 61140 (2002-03)) | |
| Weight: | 2,000 g | |
| Dimensions: | 208 mm x 152.6 mm x 175.5 mm | |
Ambient data |
| Electromagnetic compatibility (EMC): | EN 61000-6-2 (2001-10) / EN 61000-6-3 (2001-10) / EN 61000-6-3/A11 (2004-07) | |
| Vibration resistance: | EN 60068-2-6 (1995) | |
| Shock resistance: | EN 60068-2-27 (1993) | |
| Ambient operating temperature: | -30 °C ... 35 °C | |
| Storage temperature: | -20 °C ... 70 °C | |
| Permissible relative humidity: | ± 90 %, non-condensing | |
| Ambient light safety: | 2,000 lx, on bar code | |
| Bar code print contrast (PCS): | ≥- 60 % | |
*изображение на сайте может отличаться от реального