Features |
| Version: | Short Range | |
| Connection type: | Standard | |
| Reading field: | Oscillating mirror | |
| Scanner design: | Line scanner | |
| Focus: | Fixed focus | |
| Light source: | Visible red light (650 nm) | |
| MTBF: | 20,000 h | |
| Laser class: | 2 (DIN EN 60825-1) | |
| Field of view: | ≤- 50 ° | |
| Scanning frequency: | 300 Hz ... 800 Hz | |
| Code resolution: | 0.2 mm ... 0.5 mm | |
| Reading distance (at code resolution): | 45 mm ... 210 mm (0.5 mm) | |
| Oscillating mirror functions: | Fixed (adjustable position), One shot, Oscillating (variable or fixed amplitude) | |
| Oscillation frequency: | 0.5 Hz ... 4 Hz | |
| Angle of deflection: | -20 ° ... 20 ° (can be adjusted via software) | |
Performance |
| Bar code types: | Interleaved 2 of 5, All current code types, Codabar, Code 128, Code 39, Code 93, EAN, EAN 128, UPC | |
| Print ratio: | 2:1 ... 3:1 | |
| No. of codes per scan: | 1 ... 20 (Standard decoder), 1 ... 6 (SMART decoder) | |
| No. of codes per reading interval: | 1 ... 50 (auto-discriminating) | |
| No. of characters per reading interval: | 500 | |
| No. of multiple readings: | 1 ... 99 | |
Interfaces |
| Serial (RS-232, RS-422/485): | Yes | |
| Remark (Serial (RS-232, RS-422/485)): | AUX (only RS-232) | |
| Function (Serial (RS-232, RS-422/485)): | Host, AUX | |
| Data transmission rate (Serial (RS-232, RS-422/485)): | 300 Baud ... 57,600 Baud , AUX: 9,600 Baud | |
| Ethernet: | Yes | |
| Remark (Ethernet): | Optional via external connection module (CDM + CMF) | |
| CAN bus: | Yes | |
| Function (CAN bus): | SICK CAN sensor network (Master/Slave, Multiplexer) | |
| Protocol (CAN bus): | CANopen®, CSN (SICK CAN Sensor Network) | |
| Data transmission rate (CAN bus): | 10 kbit/s ... 1 Mbit/s | |
| PROFIBUS: | Yes | |
| Remark (PROFIBUS): | Optional via external connection module (CDM + CMF) | |
| PROFINET: | - | |
| DeviceNet: | Yes | |
| Remark (DeviceNet): | Optional via external connection module (CDM + CMF) | |
| Switching inputs: | 2 (“Sensor 1”, “Sensor 2”) | |
| Switching outputs: | 2 (“Result 1”, “Result 2”) | |
| Reading pulse: | Non-powered, Reflector polling, "Sensor 1" switching input, Serial interface | |
| Optical indicators: | 4 LEDs (function indicator) | |
| Acoustic indicators: | Beeper/buzzer (can be switched off, can be allocated as a result status indication function) | |
Mechanics/electronics |
| Electrical connection: | 1 15-pin D-Sub HD plug (0.9 m) | |
| Operating voltage: | 10 V DC ... 30 V DC 1) | |
| Power consumption: | 6.15 W | |
| Housing: | Die-cast zinc, does not contain paint wetting impairment substances | |
| Housing color: | Light blue (RAL 5012) | |
| Enclosure rating: | IP 65 (EN 60529 (1991-10)) | |
| Protection class: | III (EN 61140 (2002-03)) | |
| Weight: | 620 g, with connecting cable | |
| Dimensions: | 99.8 mm x 92.2 mm x 37.8 mm | |
Ambient data |
| Electromagnetic compatibility (EMC): | EN 61000-6-2 (2001-10) / EN 61000-6-4 (2001-10) | |
| Vibration resistance: | IEC 60068-2-27 (1993) | |
| Shock resistance: | IEC 600682-6 (1995) | |
| Ambient operating temperature: | 0 °C ... 40 °C | |
| Storage temperature: | -20 °C ... 70 °C | |
| Permissible relative humidity: | ± 90 %, non-condensing | |
| Ambient light safety: | 2,000 lx, on bar code | |
| Bar code print contrast (PCS): | ≥- 60 % | |
General notes |
| Life cycle phase: | Available until September 30th, 2013 | |
*изображение на сайте может отличаться от реального