Luminescence sensors
LUT2, LUT2-2
 
Model NameLUT2-2N1116
Part No.1048506
 

Самое главное

  • Small plastic housing
  • High system sensitivity
  • Static teach-in on mark and/or background via control panel or control cable
  • Fast switching speed 500 Hz and 2 kHz

    Преимущества

  • Compact size enables easy integration into any machine
  • Fast and easy setup saves time and money
  • Increased reliability and precision enable fast response time
     
       
     
     

    Features
    Dimensions (L x W x H):22 mm x 12 mm x 40 mm
    Sensing distance 1):12.5 mm
    Operating range:8 mm 20 mm
    Light source 2) 3):UV-LED
    Light emission:long side
    Light spot size 4):2 mm x 2.5 mm
    Light spot direction:Vertical
    Receiving filters:KV 418 (standard)
    Receiving range:450 nm ... 750 nm
    Adjustment:Static 2-point teach-in
    Switching mode 5):Light/dark switching
    1) From front edge of lens  2) Average service life of 100,000 h at TA = +25 °C  3) Wave length: 370 nm  4) At sensing distance  5) L/D switching via teach-in  


    Mechanics/electronics
    Supply voltage Vs 1):DC 12 V ... 24 V
    Residual ripple 2):≤- 5 Vpp
    Power consumption 3):≤- 30 mA
    Switching frequency 4):500 Hz / 2 kHz, depending on the mark intensity
    Response time 5):1 ms / 250 µs
    Switching output:NPN: HIGH = approx. VS / LOW ≤- 2 V
    Switching output:NPN
    Output current Imax.:≤- 100 mA
    Input, teach-in (ET):NPN:
    Teach: U < 2 V
    Run: U = 10 V ... < UV
    Connection type:Connector M12, 4-pin
    Protection class 6):II
    Circuit protection:Output Q short-circuit protected
    Interference suppression
    VS connections reverse-polarity protected
    Enclosure rating:IP 67
    Weight:Ca. 11 g
    Housing material:ABS
    1) Limit values: DC 12 V (-10 %) ... DC 24 V (+20 %). Operation in short-circuit protected network max. 8 A  2) May not exceed or fall short of VS tolerances  3) Without load  4) With light/dark ratio 1:1  5) Signal transit time with resistive load  6) Reference voltage DC 50 V  


    Ambient data
    Ambient temperature:Operation: -10 ... 55 °C
    Storage: -25 ... 75 °C
    Shock load:According to IEC 60068