Features |
| Brief description: | Modular connection module for one sensor with pre-mounted CMF400 PROFIBUS module (Interface 2 x M12) and integrated CMC parameter cloning module | |
| Supported products: | CLV42x, CLV43x, CLV44x, CLV45x, CLV62x, CLV63x, CLV64x, CLV65x, ICR84x-2, ICR85x-2 | |
| Supports cloning module (CMC): | Yes | |
| Supports display module (CMD): | Yes | |
| Supports power supply module (CMP): | Yes | |
| Supports fieldbus gateway (CMF): | Integrated (PROFIBUS) | |
Interfaces |
| CAN bus: | Yes | |
| Remark (CAN bus): | Depending on sensor connected | |
| Ethernet: | Yes | |
| Remark (Ethernet): | Corresponding CMF fieldbus gateway additionally necessary | |
| PROFIBUS: | Yes | |
| Remark (PROFIBUS): | CMF400 PROFIBUS-Gateway already integrated | |
| PROFINET: | - | |
| DeviceNet: | Yes | |
| Remark (DeviceNet): | Corresponding CMF fieldbus gateway additionally necessary | |
| Switching inputs: | Depending on sensor connected | |
| Switching outputs: | Depending on sensor connected | |
| Optical indicators: | 5 LED | |
| Serial (RS-232, RS-422/485): | 1 | |
| Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | |
Mechanics/electronics |
| Power consumption: | Power consumption of the sensor + 1 W | |
| Housing: | Polycarbonat | |
| Enclosure rating: | IP 65 (DIN 40 050) 1) | |
| Protection class: | III (VDE 0106) | |
| Weight: | 800 g | |
| Dimensions: | 192 mm x 167 mm x 70 mm | |
| Housing color: | Blue (RAL 5012) | |
| Scanner connection: | 15-pin D-Sub HD socket | |
| Service plug: | 9-pin D-Sub plug (internal) | |
Ambient data |
| Ambient operating temperature: | 0 °C ... 40 °C | |
| Storage temperature: | -20 °C ... 70 °C | |
| Permissible relative humidity: | ± 90 %, non-condensing | |
*изображение на сайте может отличаться от реального