Functions |
| Muting (with M4000 Advanced, M4000 A/P): | Yes | |
| Concurrence monitoring (with M4000 Advanced, A/P): | Yes | |
| Override (with M4000 Advanced, A/P): | Yes | |
| Monitoring total muting time (with M4000 Advanced, A/P): | Yes | |
| Sensor gap monitoring (with M4000 Advanced, A/P): | Yes | |
| Sensor test (with M4000 Advanced, A/P): | Yes | |
| Partial blanking (with M4000 Advanced, A/P): | Yes | |
| End of muting by ESPE (with M4000 Advanced, A/P): | Yes | |
| Belt stop (with M4000 Advanced, A/P): | Yes | |
| Number of muting sensors: | 4 | |
| Connection muting lamp: | Yes | |
| Connection belt stop signal: | Yes | |
| Connection additional signal C1: | Yes | |
| Connection reset control switch: | Yes | |
| Connection override control switch: | Yes | |
Technical data |
| Protection class: | III (EN 50178:1998) | |
| Enclosure rating: | IP 65 (IEC 60529) | |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) 1) | |
| Category: | Category 4 (EN ISO 13849) 2) | |
| Performance level: | PL e (EN ISO 13849) 3) | |
| PFHd: | 1.0 * 1E-08 4) | |
| TM (mission time): | 18 a 5) | |
| Dimensions (W x H x D): | 76.5 mm x 225.2 mm x 40 mm | |
| Supply voltage from, typical, to: | 19.2 V DC, 24 V DC, 28.8 V DC | |
| Maximum power consumption: | 2 | |
| Type of muting sensors: | inductive sensors, mechanical switches, Optical sensors, controller signals | |
| Connection type: | Socket M12 x 5 | |
| Switching voltage HIGH inputs from, typical, to: | 11 V DC, 24 V DC, 30 V DC | |
| Input current HIGH from, typical, to: | 6 mA, 10 mA, 15 mA | |
| Switching voltage LOW inputs from, typical, to: | -30 V DC, 0 V DC, 5 V DC | |
| Input current LOW from, typical, to: | -0.5 mA, 0 mA, 1.5 mA | |
| Supply voltage outputs from, typical, to: | 15 V DC, 24 V DC, 28.8 V DC | |
| Supply current outputs for muting sensors: | 400 mA 6) | |
| Supply current outputs for reset, override or C1: | 500 mA 7) | |
| Switching voltage HIGH output, muting lamp, from, typical, t: | 15 V DC, 24 V DC, 28.8 V DC | |
| Output current HIGH (monitored), muting lamp, from, to: | Monitored, 20 mA, 400 mA 8) | |
| Output current HIGH (not monitored), muting lamp, from, to: | Not monitored, 0 mA, 400 mA 9) | |
| Maximum output power HIGH, muting lamp: | 5 W | |
| Maximum cable length to ESPE: | 10 m | |
| Minimum conductor cross-section: | 0.34 mm? | |
| Wire cross section from ... to: | 0.34 mm? | |
| Maximum cable resistance: | < 0.5 Ω- (per cable) | |
| Ambient operating temperature from ... to: | -10 °C ... 55 °C | |
| Storage temperature from ... to: | -25 °C ... 70 °C | |
| Air humidity from ... to: | 15 % ... 95 %, non-condensing | |
| Vibration resistance (checked to): | 5 (IEC 60068-2-6) | |
| Oscillation frequency from ... to: | 10 ... 55 | |
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) | |
| Housing material: | Die-cast aluminum (powder coated) | |
| Material, connector strip: | Polyamide | |
| Mounting: | flexible mounting to the M4000 Advanced or directly in the system | |
| System part: | Safety relays | |