Ничего не куплено!
fiber-optic sensors | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Features | |||
Device type: | Base unit 1) | ||
Dimensions (W x H x D): | 10.5 mm x 34.8 mm x 68.9 mm | ||
Sensing range max.: | 0 m ... 4 m, through-beam system 2) 3) | ||
Sensing range: | 0 mm ... 480 mm, proximity system 0 ... 2 m, through-beam system 4) 5) 6) | ||
Light source: | LED 7) | ||
Type of light: | Visible red light | ||
Wave length: | 650 nm | ||
Sensitivity adjustment: | Teach-in button Cable +/- increment button, manual | ||
Adjustment of operating distance: | Cable, +/- increment button, manual, Teach-in button | ||
Teach-in: | Menu-controlled | ||
Time type: | Without time delay time delay off switch on delay one shot | ||
Delay time: | Programmable: 0 ... 9,999 ms | ||
Indication: | Display | ||
Sensor/detection principle: | Fiber-optic photoelectric sensor | ||
Housing design (light emission): | Rectangular | ||
Display: | LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters |
1) Up to 15 expansion units can be connected 2) Scanning range at response time 2 ms. Range reduction at shorter response time (see LL3/ WLL190T-2 table) 3) LL3-TB02 and tip adapter LL3-TA01 4) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). sensing distance with 2 ms response time. sensing distance reduction with shorter response time (see tables LL3/WLL190T-2) 5) LL3-DB01 6) LL3-TB01 7) Average service life 100,000 h at Ta = +25 °C |
Mechanics/electronics | |||
Enclosure rating: | IP 50 1) | ||
Supply voltage: | 10 V DC ... 24 V DC 2) | ||
Residual ripple: | ≤- 10 % 3) | ||
Power consumption: | ≤- 50 mA | ||
Switching output: | NPN, light/dark-switching, manually selectable, open collector 4) 5) | ||
Output current Imax.: | ≤- 100 mA | ||
Response time: | ≤- 2 ms ≤- 60 µs ≤- 250 µs | ||
Switching frequency: | 8,333 Hz 2,000 Hz 250 Hz | ||
Connection type: | Cable, 4-wire, 2 m 6) | ||
Cable material: | PVC | ||
Conductor cross-section: | 0.2 mm? | ||
Protection class: | III | ||
Circuit protection: | A B C D 7) 8) 9) 10) | ||
Special device: | 0 | ||
Housing material: | ABS/PC | ||
Ambient operating temperature: | -25 °C ... 55 °C 11) | ||
Ambient storage temperature: | -40 °C ... 70 °C | ||
Weight: | 20 g | ||
Angle of dispersion: | Ca. 65 ° 12) |
1) With correctly attached fibre-optic cable LL3 and closed protection hood 2) +- 10% 3) May not exceed or fall short of VS 4) Q1, Q2 5) Selectable Q2, external teach or counter reset 6) Do not bend below 0 °C 7) A = VS connections reverse-polarity protected 8) B = inputs and output reverse-polarity protected 9) C = interference suppression 10) D = outputs overcurrent and short-circuit protected 11) Operating temperature fluctuates according to number of devices connected: 4-8 devices: -25 °C ... +50 °C (output current 50 mA) / 9–16 devices: –25 °C … +45 °C (output current 20 mA) 12) See LL3 fiber-optic data |