Features |
| Field of application: | Outdoor, Security | |
| Version: | Mid Range | |
| Variant: | Lite | |
| Resolution power: | Standard Resolution | |
| Light source: | Infrared (905 nm) | |
| Laser class: | 1 (IEC 60825-1 (2007-6)), eye-safe | |
| Field of view: | 190 ° | |
| Scanning frequency: | 25 Hz / 35 Hz / 50 Hz / 75 Hz | |
| Angular resolution: | 0.25 ° 0.5 ° 1 ° | |
| Heating: | Yes | |
| Operating range: | 0 m ... 80 m | |
| Max. range with 10 % reflectivity: | 40 m | |
| Spot size: | 11.9 mrad | |
| Amount of evaluated echoes: | 2 | |
| Fog correction: | Yes | |
Performance |
| Response time: | ≥- 13 ms | |
| Detectable object shape: | Almost any | |
| Systematic error 1): | ± 25 mm (1 m ... 10 m) ± 35 mm (10 m ... 20 m) ± 50 mm (20 m ... 30 m) | |
| Statistical error 2): | ± 14 mm (20 m ... 30 m) ± 6 mm (1 m ... 10 m) ± 8 mm (10 m ... 20 m) | |
| Integrated application: | Field evaluation | |
| Number of field sets: | 4 fields | |
| Simultaneous processing cases: | 4 | |
Interfaces |
| Serial (RS-232, RS-422): | Yes | |
| Function (Serial (RS-232, RS-422)): | Host | |
| Data transmission rate (Serial (RS-232, RS-422)): | 9.6 kBaud ... 500 kBaud | |
| Ethernet: | Yes | |
| Function (Ethernet): | Host | |
| Data transmission rate (Ethernet): | 10/100 Mbit | |
| Protocol (Ethernet): | TCP/IP, OPC | |
| CAN bus: | - | |
| PROFIBUS: | - | |
| PROFINET: | - | |
| DeviceNet: | - | |
| USB: | Yes | |
| Function (USB): | AUX | |
| Data transmission rate (USB): | 9.6 kBaud ... 500 kBaud | |
| Switching inputs: | 2 | |
| Switching outputs: | 3 (2 relay, 1 digital) | |
| Optical indicators: | 5 LEDs (additional 7-segment display) | |
| Remark (USB): | Mini USB | |
Mechanics/electronics |
| Electrical connection: | 4 M12 circular plug-in connector | |
| Operating voltage: | 24 V DC | |
| Power consumption: | 22 W, + 55 W heating (typical) | |
| Housing color: | Gray (RAL 7032) | |
| Enclosure rating: | IP 67 (EN 60529, Section 14.2.7) | |
| Protection class: | III (EN 60529, Section 14.2.7) | |
| Weight: | 3.7 kg | |
| Dimensions: | 160 mm x 155 mm x 185 mm | |
Ambient data |
| Object remission: | 2 % ... > 1,000 % (reflectors) | |
| Electromagnetic compatibility (EMC): | EN 61000-6-2:2005 / EN 61000-6-3 (2001-10) | |
| Vibration resistance: | EN 60068-2-6 (1995-04) | |
| Shock resistance: | EN 60068-2-27 (1993-03) / EN 60068-2-29 (1993-04) | |
| Ambient operating temperature: | -30 °C ... 50 °C | |
| Storage temperature: | -30 °C ... 70 °C | |
| Ambient light safety: | 70,000 lx | |
General notes |
| Note on use: | Not suitable for personnel protection | |