Features |
| Field of application: | Indoor, Security | |
| Version: | Short Range | |
| Light source: | Infrared (905 nm) | |
| Laser class: | 1 (IEC 60825-1 (2007-3)) | |
| Field of view: | 270 ° | |
| Scanning frequency: | 50 Hz
| |
| Angular resolution: | 0.25 ° 0.5 ° | |
| Operating range: | 0.5 m ... 20 m | |
| Max. range with 10 % reflectivity: | 18 m | |
| Amount of evaluated echoes: | 2 | |
Performance |
| Response time: | 20 ms | |
| Detectable object shape: | Almost any | |
| Systematic error 1): | ± 30 mm | |
| Statistical error 2): | ± 12 mm | |
| Integrated application: | Field evaluation | |
| Number of field sets: | 10 fields | |
| Simultaneous processing cases: | 10 | |
Interfaces |
| Serial (RS-232): | Yes | |
| Function (Serial (RS-232)): | Host, AUX | |
| Data transmission rate (Serial (RS-232)): | 9.6 kBaud ... 115.2 kBaud | |
| Ethernet: | Yes | |
| Function (Ethernet): | Host | |
| Data transmission rate (Ethernet): | 10/100 Mbit | |
| Protocol (Ethernet): | TCP/IP | |
| CAN bus: | Yes | |
| Function (CAN bus): | Outputs extension | |
| PROFIBUS: | - | |
| PROFINET: | - | |
| DeviceNet: | - | |
| Switching inputs: | 4 (2 x IN, 2 x increment (1-phase)) | |
| Switching outputs: | 3 (2 relay, 1 digital) | |
| Optical indicators: | 1 7-segment display (plus 5 LEDs showing device status, contamination warning and initial condition, both can be activated) | |
Mechanics/electronics |
| Electrical connection: | 1 system plug with screw terminal block | |
| Operating voltage: | 9 V DC ... 30 V DC | |
| Power consumption: | 20 W | |
| Housing color: | Black (RAL 9005) | |
| Enclosure rating: | IP 65 (EN 60529, Section 14.2.5) | |
| Protection class: | III (EN 50178 (1997-10)) | |
| Weight: | 1.1 kg, without connecting cables | |
| Dimensions: | 105 mm x 102 mm x 152 mm | |
Ambient data |
| Object remission: | 2 % ... > 1,000 % (reflectors) | |
| Electromagnetic compatibility (EMC): | EN 61000-6-2:2005 / EN 61000-6-4 (2007-01) | |
| Vibration resistance: | EN 60068-2-6 (1995-04) | |
| Shock resistance: | EN 60068-2-27 (1993-03) | |
| Ambient operating temperature: | 0 °C ... 45 °C | |
| Storage temperature: | -30 °C ... 70 °C | |
| Ambient light safety: | 40,000 lx | |
General notes |
| Items supplied: | Mounting protection bracket VdS 1 (long), LMS12x VdS (indoor) | |
| Note on use: | Not suitable for personnel protection | |
*изображение на сайте может отличаться от реального