Ничего не куплено!
Laser measurement technology | |||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||
Features | |||
Field of application: | Outdoor | ||
Version: | Mid Range | ||
Variant: | PRO | ||
Resolution power: | Standard Resolution | ||
Light source: | Infrared (905 nm) | ||
Laser class: | 1 (IEC 60825-1 (2007-6)), eye-safe | ||
Field of view: | 190 ° | ||
Scanning frequency: | 25 Hz / 35 Hz / 50 Hz / 75 Hz / 100 Hz | ||
Angular resolution: | 0.167 ° 0.25 ° 0.333 ° 0.5 ° 0.667 ° 1 ° | ||
Heating: | Yes | ||
Operating range: | 0 m ... 80 m | ||
Max. range with 10 % reflectivity: | 40 m | ||
Spot size: | 11.9 mrad | ||
Amount of evaluated echoes: | 5 | ||
Fog correction: | Yes |
Performance | |||
Response time: | ≥- 10 ms | ||
Detectable object shape: | Almost any | ||
Systematic error 1): | ± 25 mm (1 m ... 10 m) ± 35 mm (10 m ... 20 m) ± 50 mm (20 m ... 30 m) | ||
Statistical error 2): | ± 14 mm (20 m ... 30 m) ± 6 mm (1 m ... 10 m) ± 8 mm (10 m ... 20 m) | ||
Integrated application: | Field evaluation | ||
Number of field sets: | 10 fields | ||
Simultaneous processing cases: | 10 |
1) 2) Typical value- actual value depends on environmental conditions. |
Interfaces | |||
Serial (RS-232, RS-422): | Yes | ||
Function (Serial (RS-232, RS-422)): | Host | ||
Data transmission rate (Serial (RS-232, RS-422)): | 9.6 kBaud ... 500 kBaud | ||
Ethernet: | Yes | ||
Function (Ethernet): | Host | ||
Data transmission rate (Ethernet): | 10/100 Mbit | ||
Protocol (Ethernet): | TCP/IP, OPC | ||
CAN bus: | Yes | ||
Function (CAN bus): | Outputs extension | ||
PROFIBUS: | - | ||
PROFINET: | - | ||
DeviceNet: | - | ||
USB: | Yes | ||
Function (USB): | AUX | ||
Data transmission rate (USB): | 9.6 kBaud ... 500 kBaud | ||
Switching inputs: | 4 (Encoder) | ||
Switching outputs: | 6 | ||
Optical indicators: | 5 LEDs (additional 7-segment display) | ||
Remark (USB): | Mini USB |
Mechanics/electronics | |||
Electrical connection: | 4 M12 circular plug-in connector | ||
Operating voltage: | 24 V DC | ||
Power consumption: | 22 W, + 55 W heating (typical) | ||
Housing color: | Gray (RAL 7032) | ||
Enclosure rating: | IP 67 (EN 60529, Section 14.2.7) | ||
Protection class: | III (EN 60529, Section 14.2.7) | ||
Weight: | 3.7 kg | ||
Dimensions: | 160 mm x 155 mm x 185 mm |
Ambient data | |||
Object remission: | 2 % ... > 1,000 % (reflectors) | ||
Electromagnetic compatibility (EMC): | EN 61000-6-2:2005 / EN 61000-6-3 (2001-10) | ||
Vibration resistance: | EN 60068-2-6 (1995-04) | ||
Shock resistance: | EN 60068-2-27 (1993-03) / EN 60068-2-29 (1993-04) | ||
Ambient operating temperature: | -30 °C ... 50 °C | ||
Storage temperature: | -30 °C ... 70 °C | ||
Ambient light safety: | 70,000 lx |
General notes | |||
Note on use: | Not suitable for personnel protection |