Features |
| Field of application: | Indoor | |
| Version: | Short Range | |
| Reading field: | Front | |
| Light source: | Visible red light (650 nm) | |
| Laser class: | 2, in standby mode laser class 1 according to IEC60825-1:2007 | |
| Field of view: | 70 ° | |
| Scanning frequency: | 180 Hz ... 500 Hz | |
| Angular resolution: | 0.1° ... 1.0° | |
| Operating range: | 0.7 m ... 3 m | |
| Max. range with 10 % reflectivity: | 3 m | |
Performance |
| Response time: | ≥- 2 ms | |
| Detectable object shape: | Almost any | |
| Systematic error 1): | ± 4 mm | |
| Statistical error 2): | ± 10 mm ± 3 mm | |
| Integrated application: | Level Control | |
Interfaces |
| Serial (RS-232, RS-422): | Yes | |
| Function (Serial (RS-232, RS-422)): | Host, AUX | |
| Ethernet: | Yes | |
| Function (Ethernet): | Host | |
| Data transmission rate (Ethernet): | 10 Mbit, half-duplex | |
| Protocol (Ethernet): | TCP/IP | |
| CAN bus: | - | |
| PROFIBUS: | - | |
| PROFINET: | - | |
| DeviceNet: | - | |
| Switching inputs: | 4 | |
| Switching outputs: | 5 (4 x PNP / analog 1 x 4 ... 20 mA) | |
| Optical indicators: | 6 LEDs | |
Mechanics/electronics |
| Operating voltage: | ≤- 24 V DC± 15 % | |
| Power consumption: | 25 W | |
| Housing: | Die-cast aluminum | |
| Housing color: | Light blue (RAL 5012) | |
| Enclosure rating: | IP 20 (DIN 40 050) 1) | |
| Weight: | 2.3 kg | |
| Dimensions: | 179 mm x 107 mm x 130 mm | |
Ambient data |
| Object remission: | 6.5 % ... 200 % | |
| Electromagnetic compatibility (EMC): | EN 61000G6G2:2001 / EN 61000G6G4:2001 | |
| Vibration resistance: | EN 60068G2G6, G27, G29, G64 | |
| Shock resistance: | EN 60068G2G6, G27, G29, G64 | |
| Ambient operating temperature: | 0 °C ... 40 °C | |
| Storage temperature: | -20 °C ... 70 °C | |
General notes |
| Selectable region of interest (ROI): | From 50 mm x 3,000 mm to 1,000 mm x 1,750 mm | |
| Number of columns: | Up to 50 equidistant or 30 freely positionable | |
| Minimum column width: | 50 mm | |
| Minimum detectable object: | 30 mm x 30 mm | |
| Smallest height threshold above the container floor: | 20 mm | |
| Switching threshold output: | Telegram, switch outputs or analog output | |
| Output of height values in the columns: | Analog output, Telegram | |
| Note on use: | Not suitable for personnel protection | |
*изображение на сайте может отличаться от реального