Features |
| Field of application: | Indoor | |
| Version: | Mid Range | |
| Light source: | Infrared (855 nm) | |
| Laser class: | 1, eye-safe | |
| Field of view: | 360 ° | |
| Scanning frequency: | 8 Hz | |
| Angular resolution: | 0.1 ° | |
| Operating range: | 1.2 m ... 28.5 m (28.5 m on reflectors) | |
| Max. range with 10 % reflectivity: | 28.5 m | |
Performance |
| Detectable object shape: | Reflector | |
| Integrated application: | Navigation | |
| Reflector memory: | Max. 5,120 (in 160 layers) | |
| Positioning accuracy: | ± 4 mm | |
Interfaces |
| Serial (RS-232): | Yes | |
| Data transmission rate (Serial (RS-232)): | 19,200 Baud | |
| Ethernet: | - | |
| CAN bus: | - | |
| PROFIBUS: | - | |
| PROFINET: | - | |
| DeviceNet: | - | |
| Optical indicators: | 4 LEDs (status displays) | |
Mechanics/electronics |
| Electrical connection: | 1 Flange plug, round 8 pin for DC 24 V power supply, Flange plug, round 14 pin for RS-232 data interface | |
| Operating voltage: | ≥- 24 V DC pos2 kein value !! ± 25 % | |
| Power consumption: | 24 W | |
| Housing: | Die-cast aluminum | |
| Housing color: | Light blue (RAL 5012) | |
| Enclosure rating: | IP 65 (EN 60529) | |
| Protection class: | I | |
| Weight: | 3.3 kg | |
| Dimensions: | 176 mm x 178 mm x 115 mm 1) | |
Ambient data |
| Electromagnetic compatibility (EMC): | EN 61000-6-2 / EN 61000-6-4 | |
| Vibration resistance: | IEC 68-2-6 | |
| Shock resistance: | IEC 68-2-29 | |
| Ambient operating temperature: | 0 °C ... 50 °C | |
| Storage temperature: | -20 °C ... 70 °C | |
| Permissible relative humidity: | 90 %, non-condensing | |
| Reflector marks: | Stripes: Width > 100 mm- height > 500 mm, Cylindrical: diameter > 80 mm- height > 500 mm | |
General notes |
| Note on use: | Not suitable for personnel protection | |