Performance |
| Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | |
| Repeatability 1): | ± 0.5 mm | |
| Accuracy: | ± 2 mm | |
| Light source 2): | Laser, red | |
| Laser protection class: | 2 (EN 60825-1 / CDRH) | |
| Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | |
| Output rate: | Synchronous to PLC request | |
| Measuring range 3): | 0.15 m ... 100 m, On reflective tape "Diamond Grade" | |
| Acceleration (max.): | 15 m/s? | |
| Internal measurement cycle: | 1 ms | |
| Max. movement speed: | 10 m/s | |
| Dead time: | 2 ms | |
Interfaces |
| Switching output 1): | Push-pull: PNP/NPN (100 mA) MF1, MF2 | |
| Multifunctional input 2): | 1 x MF1 | |
| Data interface: | PROFINET | |
Mechanics/electronics |
| Supply voltage Vs: | DC 18 V ... 30 V | |
| Residual ripple 1): | < 5 Vpp | |
| Initialization time 2): | Typ. 1.5 s | |
| Indication: | 6 digit 5 x 7 dot matrix display | |
| Weight 3): | Ca. 800 g ... 1,600 g | |
| Output current IA 4): | ≤- 100 mA | |
| Power consumption: | At 24 V DC < 250 mA | |
| Connection type: | Connector M12, SPEEDCON™ compatible | |
| Housing material: | Aluminum/zinc die-cast | |
Ambient data |
| Enclosure rating: | IP 65 | |
| Protection class: | III | |
| EMC 1): | EN 61000-6-2 EN 61000-6-4 | |
| Effect of air pressure: | 0.3 ppm/hPa | |
| Effect of air temperature: | 1 ppm/K | |
| Temperature drift: | Typ. 0.1 mm/K | |
| Ambient temperature 2): | Operation: -20 ... 55 °C Operation with cooling case: -20 ... 75 °C Storage: -40 ... 75 °C | |
| Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 | |