Performance |
| Resolution: | 0.05 mm ... 5 mm | |
| Repeatability 1) 2): | 3 mm | |
| Accuracy: | ± 6 mm | |
| Light source 3): | Laser, red | |
| Laser protection class: | 2 (EN 60825-1 / CDRH) | |
| Typ. light spot size (distance): | 130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m) | |
| Output rate: | 2 ms | |
| Measuring range: | 0.15 m ... 220 m, on Diamond Grade | |
| Max. movement speed: | 10 m/s | |
Interfaces |
| Switching output 1): | Push-pull: PNP/NPN (100 mA) | |
| Multifunctional input 2) 3): | 1 x MF | |
| Data interface: | DeviceNet | |
Mechanics/electronics |
| Supply voltage Vs: | DC 18 V ... 30 V , limit values | |
| Residual ripple 1): | < 5 Vpp | |
| Initialization time 2): | 1.5 s | |
| Indication: | Display | |
| Weight: | Ca. 1,650 g | |
| Output current IA 3): | ≤- 100 mA | |
| Power consumption: | At 24 V DC < 250 mA | |
| Connection type: | Connector 1 x M16, 8-pin | |
Ambient data |
| Enclosure rating: | IP 65 | |
| Protection class 1): | II | |
| EMC: | EN 61000-6-2, EN 55011: Class B | |
| Effect of air pressure: | 0.3 ppm/hPa | |
| Effect of air temperature: | 1 ppm/K | |
| Temperature drift: | Typ. 0.1 mm/K | |
| Ambient temperature: | Operation: -10 ... 55 °C Operation with cooling case: -10 ... 75 °C Storage: -25 ... 75 °C | |
| Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 | |
*изображение на сайте может отличаться от реального