Performance |
| Resolution: | ≤- 0.1 mm | |
| Repeatability 1) 2): | 1 mm | |
| Accuracy 3): | ± 3 mm | |
| Light source 4): | Laser, red | |
| Laser protection class: | 2 (EN 60825/21 CFR 1.040) | |
| Typ. light spot size (distance): | 10 mm (at 7 m) 100 mm (at 70 m) 45 mm (at 30 m) | |
| Output rate: | 0.15 s / 6 s | |
| Measuring range: | 0.2 m ... 30 m, 6 % remission 0.2 m ... 70 m, 90 % remision | |
Interfaces |
| Resolution CAN: | 0.1 mm | |
| CAN address: | 11 bit, setup via display | |
| Data interface: | CAN (Layer 2) | |
| Laser off input: | > 12 V | |
Mechanics/electronics |
| Supply voltage Vs: | DC 10 V ... 30 V , reverse polarity protected, Us ≥- DC 24 V for devices with heating | |
| Residual ripple 1): | 5 Vpp | |
| Initialization time: | 500 ms | |
| Weight: | 1,000 g | |
| Power consumption: | Typ. 22 W | |
| Connection type: | Connector M12, 8-pin | |
Ambient data |
| Enclosure rating: | IP 65 | |
| Protection class 1): | II | |
| EMC: | EN 61000-6-2, EN 55011 EN 60947-5-7: 2003-9 | |
| Temperature drift: | Typ. 0.05 mm/K | |
| Ambient temperature: | Operation with heating: -40 ... 50 °C Operation with cooling case: -40 ... 75 °C Storage: -25 ... 75 °C | |
| Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 | |
*изображение на сайте может отличаться от реального