Dx500, DT500, QA Sick DT500-A411 (1040465)

Dx500, DT500, Q<sub>A</sub> Sick DT500-A411 (1040465)
Производитель: Sick
Артикул: 1040465
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
Long range distance sensors
Dx500, DT500, QA
 
Model NameDT500-A411
Part No.1040465
 

Самое главное

  • Measurement range 0.2 m ... 70 m
  • One analog output, RS-422 or CAN
  • Highest measurement resolution, repeatability and accuracy without a reflector
  • Simple adjustment using red laser light
  • Metal housing with integrated heating option for cold store applications
  • Weather protection housing optional
  • Alignment bracket optional

    Преимущества

  • High-precision measurement reliably indicates product position for exact machine control, reducing scrap and increasing throughput
  • Red laser light as well as adjustable mounting brackets (optional accessory) enable fast and easy alignment, ensuring on-time and cost-effective installation
  • A tough metal housing with internal heating ensures reliability in rough ambient conditions, such as cold store warehouses
  • User-friendly display with easy-to-use menu along with external PC/PLC programming offers fast and cost-efficient setup
  • Serial interfaces or an analog output offer flexible integration into application
  • Wide measurement range of 0.2 m to 70 m enables automated measurement on natural targets where reflectors can’t be used
     
     
       

    Performance
    Resolution:12 bit
    Repeatability 1) 2):1 mm
    Accuracy 3):± 3 mm
    Light source 4):Laser, red
    Laser protection class:2 (EN 60825/21 CFR 1.040)
    Typ. light spot size (distance):10 mm (at 7 m)
    100 mm (at 70 m)
    45 mm (at 30 m)
    Output rate:150 ms
    Measuring range 5):0.2 m ... 7 m, 6 % ... 90 % remission
    1) 3) 6 % ... 90 % remission  2) Statistical error 1 ?  4) Average service life of 50,000 h at TA = +25 °C  5) Unique up to 7 m  


    Interfaces
    Multifunctional input 1):> 12 V
    Analog output:0 mA ... 20 mA / 4 mA … 20 mA (VS-2 V / 0.0205 A) 2)
    Data interface:QA
    Laser off input:> 12 V
    1) Refer to function MF input  2) Max. load = Uv - 2 V / 0,0205 A  


    Mechanics/electronics
    Supply voltage Vs:DC 10 V ... 30 V , reverse polarity protected, Us ≥- DC 24 V for devices with heating
    Residual ripple 1):5 Vpp
    Initialization time:500 ms
    Weight:1,000 g
    Power consumption:Typ. 22 W
    Connection type:Connector M12, 5-pin
    1) May not fall short of or exceed VS tolerances  


    Ambient data
    Enclosure rating:IP 65
    Protection class 1):II
    EMC:EN 61000-6-2, EN 55011 EN 60947-5-7: 2003-9
    Temperature drift:Typ. 0.05 mm/K
    Ambient temperature:Operation with heating: -40 ... 50 °C
    Operation with cooling case: -40 ... 75 °C
    Storage: -25 ... 75 °C
    Mechanical load:Noise: EN 600 68-2-64
    Shock: EN 600 68-2-27 / -2-29
    Sine: EN 600 68-2-6
    1) Reference voltage DC 32 V  



    *изображение на сайте может отличаться от реального