DMT, DMT10-2, PROFIBUS DP Sick DMT10-2-2211 (1028541)

DMT, DMT10-2, PROFIBUS DP Sick DMT10-2-2211 (1028541)
Производитель: Sick
Артикул: 1028541
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
Long range distance sensors
DMT, DMT10-2, PROFIBUS DP
 
Model NameDMT10-2-2211
Part No.1028541
 

Самое главное

  • Measurement range from 0.5 m up to 155 m on natural targets
  • Excellent accuracy thanks to time-of-flight measurement
  • Easy alignment thanks to pilot laser
  • Freely programmable parameters
  • RS-422, RS-232, PROFIBUS, analog and two switching outputs
  • Near field blanking parameter for operation through a protection window
  • Models with filter for measurement of glowing, hot metal (up to 1,400 °C)

    Преимущества

  • Extremely wide measurement range of up to 155 m on natural targets offers high flexibility in applications where range is key
  • Supplementary visible alignment laser allows fast and easy alignment - even over long distances, offering fast and cost-effective installation
  • Tough metal housing design for trouble-free operation in the roughest environmental conditions
  • Non-visible, Class 1 IR laser for safe measurement and detection
  • User-friendly software with an easy-to-follow interface ensures fast and cost-optimized setup
  • Serial and analog interfaces as well as two digital switching outputs allow flexible use for varied applications
  • Integrated filter option allows for direct measurement of 1,400 °C glowing, hot targets
     
     
         

    Performance
    Resolution:≤- 1 mm
    Repeatability 1) 2) 3) 4):10 mm, 7 mm
    Accuracy 5) 6):± 10 mm
    Light source:Laser, infrared
    Laser protection class:1 (EN 60825-1:Nov.2001, IEC 60825-1:AM2:2001)
    Typ. light spot size (distance):20 mm (+ 5 x distance in m)
    Average depth:1/16/64/256/1,024
    Output rate 7):1 ms / 4,000 ms
    Aperture delay time:≥- 1 ms 8)
    Note:Electronic aperture
    Response time 9):1 ms ... 3,000 ms
    Measuring range:0.5 m ... 155 m, 90 % remision
    0.5 m ... 40 m, 6 % remission
    0.5 m ... 65 m, 18 % remission
    Cycle time:1,024 per sec.
    Special characteristic:Electronic aperture
    1) Dependant on distance and remission, 7 mm, at 6 % ... 90 % remission from 0.5 m ... 65 m, at 6 % ... 18 % remission from 0.5 m ... 40 m, at 6 % remission from 0.5 m ... 15 m  2) 4) Environmental conditions constant, min. warm-up time 30 min, average depth 1,024, statistical error 1 ?  3) Dependant on distance and remission, 10 mm, at 6 % ... 90 % remission from 60 m ... 155 m, at 6 % ... 18 % remission from 40 m ... 65 m, at 6 % remission from 15 m ... 40 m  5) 23 °C air temperature, 977 hPa, min. warm-up time 30 min.  6) When operating in ambient temperatures between +40 °C ... +55 °C the accuracy can decrease by factor 2.5  7) 8) Dependant on average setting, average depth, timeout, baud rate, data outpu and output format  9) Dependant on average setting, average depth, timeout, baud rate, data output, output format and effective dead time of aperture  


    Interfaces
    Switching output 1):Q1, Q2
    Interface for parametrization:RS-232
    Analog output:4 mA ... 20 mA, scalable
    Data interface:PROFIBUS DP
    1) Output Q short-circuit protected  


    Mechanics/electronics
    Supply voltage Vs:DC 18 V ... 30 V , limit values
    Residual ripple 1):< 5 Vpp
    Initialization time:6 s
    Weight:Ca. 1,200 g
    Output current IA:100 mA
    Power consumption 2):≤- 6 W
    Connection type:1 x cable gland, 1 x Sub-D, 9-pin
    1) May not fall short of or exceed VS tolerances  2) Without load  


    Ambient data
    Enclosure rating:IP 65
    Protection class 1):III
    EMC:EN 55011:1998 Kl. B, Gr.1 EN 61000-6-2
    Temperature drift 2) 3):Typ. 0.3 mm/K
    Typ. 0.6 mm/K
    Ambient temperature:Operation: -10 ... 55 °C
    Operation with cooling case: -10 ... 75 °C
    Storage: -25 ... 70 °C
    Mechanical load:Shock: IEC 60068-2-27, -2-29
    Sine: IEC 60068-2-6
    1) Reference voltage DC 50 V PELV-voltage (EN 50178)  2) -10° C ... 0° C, +40 °C … +55 °C  3) 0 °C ... +40 °C  



    *изображение на сайте может отличаться от реального