Features |
| Medium: | Fluids | |
| Measurement: | switch | |
| Probe length: | 3,000 mm | |
| Process pressure: | -1 bar ... 64 bar | |
| Process temperature: | -50 °C ... 150 °C | |
| WHG approval: | Yes | |
| ATEX certification: | - | |
| ATEX approval: | ATEX II 1/2G, 2G Ex d IIC T6 | |
| Fill material density: | 0.5 ... 2.5 | |
Performance |
| Accuracy of sensor element: | ± 2 mm | |
| Repeatability: | 1 | |
| Viscosity: | 0.1 mPas ... 10,000 mPas | |
Mechanical data |
| Housing material: | Aluminum | |
| Process connection: | G ? A PN 64 / 316L | |
| Wetted parts: | Stainless steel 316L (optional Ra ≤- 0.8 µm) | |
| Sensor material: | Stainless steel 316L | |
Electrical data |
| Temperature drift: | 0,03 mm/K | |
| Enclosure rating: | IP 66 | |
| Power consumption: | 5 mA ... 30 mA | |
| Protection class: | 0, 1 | |
| Initialization time: | 2 s | |
| Response time: | 500 ms | |
| Output signal: | Double relay (DPDT): 20 V DC ... 72 V DC / 20 ... 253 V AC | |
| Hysteresis: | 2 mm | |
| Output current: | > 10 UA, 3A AC, 1A DC | |
| Capacitive load: | 750 VA 54 W | |
| Inductive load: | 750 VA 54 W | |
| Connection type: | M20 x 1.5 | |
Ambient data |
| Ambient operating temperature: | -40 °C ... 70 °C | |
| Ambient storage temperature: | -40 °C ... 80 °C | |
*изображение на сайте может отличаться от реального