Features |
| Medium: | Fluids | |
| Measurement: | switch | |
| Probe length: | Probe length 117 mm | |
| Process pressure: | -1 bar ... 64 bar | |
| Process temperature: | -40 °C ... 100 °C | |
| Silicon free: | - | |
| Authorizations: | WHG approval | |
| WHG approval: | Yes | |
| Fill material density: | 0.7 | |
Performance |
| Resolution: | ≤- 1 mm | |
| Accuracy of sensor element: | ± 2 mm | |
| Repeatability: | 1 | |
| Viscosity: | 0.1 mPas ... 10,000 mPas | |
Mechanical data |
| Aseptic: | - | |
| Housing material: | Stainless steel 316L, PEI | |
| Process connection: | 1" NPT PN 64 | |
| Wetted parts: | 316L (optional Ra < 0.8 µm) | |
Electrical data |
| Temperature drift: | 0,03 mm/K | |
| Enclosure rating: | IP 67 | |
| Supply voltage: | 10 V DC ... 55 V DC | |
| Residual ripple: | ≤- 5 Vpp | |
| Power consumption: | < 10 mA | |
| Protection class: | 1 | |
| Initialization time: | 2 s | |
| Response time: | 500 ms | |
| Hysteresis: | 2 mm | |
| Output current: | < 250 mA | |
| Signal voltage HIGH: | Vs - < 3 V | |
| Signal voltage LOW: | 0 V +- 1 V | |
| Capacitive load: | 100 H | |
| Inductive load: | ≤- 1 H | |
| Connection type: | M12x1 plug connector, 4-pin | |
Ambient data |
| Ambient operating temperature: | -40 °C ... 70 °C | |
| Ambient storage temperature: | -40 °C ... 80 °C | |
*изображение на сайте может отличаться от реального