Features |
| Medium: | Fluids | |
| Measurement: | switch, continuous | |
| Probe length: | 900 mm | |
| Process pressure: | -1 bar ... 10 bar | |
| Process temperature: | -20 °C ... 100 °C | |
| GOST approval: | Yes | |
| RoHS certificate: | Yes | |
Performance |
| Maximum level change: | 500 mm/s | |
| Resolution: | < 2 mm | |
| Accuracy of sensor element: | ± 5 mm | |
| Repeatability: | ≤- 2 mm | |
| Dielectricity constant: | ≥- 5 | |
| Inactive area at process connector: | 25 mm 1) | |
| Inactive area at probe end: | 10 mm 2) | |
| Conductivity: | No limitation | |
Mechanical data |
| Housing material: | Plastic PBT | |
| Max.probe load: | 6 Nm | |
| Process connection: | G 3/4 A | |
| Wetted parts: | 1.4404, PTFE | |
Electrical data |
| Temperature drift: | < 0.1 mm/K | |
| Enclosure rating: | IP 67: EN 60529 | |
| Supply voltage: | 12 V DC ... 30 V DC 1) | |
| Power consumption: | ≤- 75 mA at 24 V without output load | |
| Protection class: | III | |
| Initialization time: | ≤- 2 s | |
| Response time: | < 400 ms | |
| Output load: | 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V | |
| Upper signal level: | 20 mA ... 20.5 mA | |
| Lower signal level: | 3.8 mA ... 4 mA | |
| Hysteresis: | min. 2 mm, free adjustable | |
| Output current: | < 100 mA | |
| Signal voltage HIGH: | Vs - 2 V | |
| Signal voltage LOW: | ≤- 2 V | |
| Capacitive load: | 100 nF | |
| Inductive load: | < 1 H | |
| Connection type: | M12x1, 5-pin | |
| EMC: | EN 61326-1:2006, 2004/108/EG | |
Ambient data |
| Ambient operating temperature: | -20 °C ... 60 °C | |
| Ambient storage temperature: | -40 °C ... 80 °C | |
*изображение на сайте может отличаться от реального