Features |
| Measuring range: | -50 °C ... 150 °C | |
| Sensor element: | Pt100 | |
| Output signal: | Pt100, 4-wire | |
Performance |
| Accuracy of sensor element: | class A according to IEC 60751 | |
Mechanics/electronics |
| Process connection: | compression fitting 1/4'' NPT, CrNi stainless steel ferrule | |
| Insertion length/diameter of probe: | 25 mm / 3 mm | |
| Housing material: | Stainless steel 1.4571 | |
| Wetted parts: | Stainless steel 1.4571 | |
| Electrical connection/enclosure rating 1): | cable gland M16 x 1.5, IP 67 | |
| Measuring current: | 0.3 mA ... 1 mA | |
| Electrical safety: | protection class: III, dielectric strength: 100 V | |
| Weight: | ca. 155 g (depending on configuration) | |
| Supply voltage: | 10 V DC ... 35 V DC for variant with transmitter 4 mA ... 20 mA | |
| Protection class III: | Yes | |
| CE-conformity: | 2004/108/EC, EN 61326-2-3 | |
| Pressure resistance: | max. 100 bar with supplied compression fitting with stainless steel ferrule | |
Ambient data |
| Ambient temperature: | -40 °C ... 125 °C | |
| Storage and transport temperature: | -40 °C ... 60 °C | |
| Shock resistance according to IEC 60751: | 500 g | |
| Vibration resistance according to IEC 60751: | 3 g | |
*изображение на сайте может отличаться от реального