Performance |
| Measuring step: | 90 °, Number of lines | |
| Error limits binary number of lines: | 0.09 ° | |
| Error limits non-binary number of lines: | 0.13 ° | |
| Measuring step deviation at binary number of lines: | 0.035 ° | |
| Measuring step deviation at non binary number of lines: | 0.07 ° | |
| Initialization time: | 40 | |
| Pulses per revolution: | 1,800 | |
Mechanical data |
| Mechanical interface: | Solid shaft, face mount flange | |
| Shaft diameter: | 8 mm x 13 mm | |
| Mass: | 0.18 kg | |
| Start up torque: | 0.6 Ncm (20 °C) | |
| Operating torque: | 0.4 Ncm (20 °C) | |
| Maximum operating speed: | 6,000 U/min | |
| Moment of inertia of the rotor: | 6 gcm? | |
| Bearing lifetime: | 2 x 10^9 revolutions | |
| Max. angular acceleration: | 3,6 x 10^9 rad/s? | |
| Permissible shaft loading radial/axial: | 40 N, 20 N | |
Electrical data |
| Electrical interface: | 10 V ... 30 V, HTL/push pull, Cable, universal, 0.5 m | |
| Connection type: | Cable, universal, 0.5 m | |
| Operating power consumption (no load): | 40 mA | |
| Supply voltage: | 10 V ... 30 V | |
| Output current: | 30 | |
| Maximum output frequency: | 200 kHz | |
| Reference signal, number: | 1 | |
| Reference signal, position: | 90 °, electronically, gated with A and B | |
Ambient data |
| EMC: | EN 61000-6-2, EN 61000-6-3 | |
| Protection class housing side with cable outlet: | IP 64 | |
| Protection class shaft side: | IP 64 | |
| Protection class standard: | IEC 60529 | |
| Air humidity: | 90 % 1) | |
| Working temperature range: | 0 °C ... 60 °C | |
| Storage temperature range: | -40 °C ... 70 °C, without package | |
| Resistance to shocks: | 50 g, 7 ms (EN 60068-2-27) | |
| Resistance to vibration: | 20, 10 ... 2,000 (EN 60068-2-6) | |