Performance |
| Initialization time: | 40 s | |
| Resolution: | 0.1 mm | |
| Smallest measuring step: | 0.025 mm | |
| Error limits knurled surface: | ± 0.5 mm | |
| Pulses per revolution: | 2,000 1) | |
Mechanical data |
| Mechanical interface: | Measuring drum, knurled surface | |
| Mass: | 0.42 kg | |
| Maximum operating speed: | 1,500 U/min | |
| Bearing lifetime: | 2 x 10^9 revolutions | |
Electrical data |
| Electrical interface: | 4.5 V ... 5.5 V, TTL/RS422, Cable, 1.5 m | |
| Connection type: | Cable, 1.5 m | |
| Supply voltage: | 4.5 V ... 5.5 V | |
| Output current: | 30 | |
| Reference signal, number: | 1 | |
| Reference signal, position: | 90 °, electronically, gated with A and B | |
Ambient data |
| EMC: | EN 61000-6-2, EN 61000-6-3 | |
| Protection class standard: | IEC 60529 | |
| Air humidity: | 90 % 1) | |
| Working temperature range: | -10 °C ... 60 °C | |
| Storage temperature range: | -40 °C ... 70 °C, without package | |
| Resistance to shocks: | 50 g, 7 ms (EN 60068-2-27) | |
| Resistance to vibration: | 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) | |
| Enclosure rating: | IP 65 | |
*изображение на сайте может отличаться от реального