AS-Interface sensor/actuator module VBA-2E2A-G12-ZAJ/EA2L

AS-Interface sensor/actuator module VBA-2E2A-G12-ZAJ/EA2L
Производитель: Pepperl+Fuchs
Артикул: VBA-2E2A-G12-ZAJ/EA2L
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
  • A/B slave with extended addressing possibility for до 62 slaves
  • One-piece housing with Нержавеющая сталь base
  • Installation without tools
  • Metal threaded inserts with SPEEDCON technology
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • красный светодиод per channel, lights up in the event of output overload
  • Communication monitoring, configurable
  • Inputs for 2-, 3-, and 4-wire sensors
  • DIN rail mounting
  • AS-Interface certificate

Технические характеристики: VBA-2E2A-G12-ZAJ/EA2L

Описание
G12 flat module
2 inputs (PNP) and 2 electronic outputs
Основные характеристики
Slave typeA/B slave
AS-Interface specificationV3.0
Required master specification&ge- V2.1
UL File NumberE87056
Показатели надежности и наработки на отказ
MTTFd270 a
Mission Time (TM)20 a
DC (Diagnostic Coverage, Диагностическое покрытие)0 %
Индикаторы состояния и их значение
LED FAULTerror display- красный светодиод
red: communication error or address is 0
red flashing: overload of sensor power supply or outputs
LED PWRAS-Interface voltage- зеленый светодиод
green: voltage OK
flashing green: address 0
LED AUXext. auxiliary voltage UAUX- dual зеленый светодиод/red
green: voltage OK
red: reverse voltage
LED INswitching state (input)- 2 желтый светодиод
LED OUTSwitching status (output)- 2 yellow/красный светодиодs
Yellow: output active
Red: output overload
Электрические параметры
Auxiliary voltage (output)24 V DC ±- 15 % PELV
Rated operational voltage26.5 ... 31.6 V from AS-Interface
Номинальный рабочий ток&le- 40 mA (without sensors) / max. 240 mA
Protection classIII
Вход
Number/Type2 inputs for 2- or 3-wire sensors (PNP), DC
option 1 input for 4-wire sensor (PNP), DC
Питаниеfrom AS-Interface
Voltage21 ... 31 V
Current loading capacity&le- 200 mA, overload and защита от короткого замыкания
Input current&le- 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)&le- 2 mA
1 (attenuated)&ge- 6 mA
Signal delay< 1 ms (input/AS-Interface)
Выход
Number/Type2 electronic outputs, PNP overload and short-circuit proof
Питаниеfrom external auxiliary voltage UAUX
Current2 A per output
4 A total (TB &le- 40 °C)
3 A total (TB &le- 70 °C)
Voltage&ge- (UAUX - 0.5 V)
Programming instructions
ProfileS-B.A.2
IO codeB
ID codeA
ID1 code7
ID2 code2
Data bits (function via AS-Interface) input output
D0 - OUT1
D1 - OUT2
D2 IN3 -
D3 IN4 -
Parameter bits (programmable via AS-i)function
P0communication monitoring
P0 = 1 (basic setting), monitoring = ON, i.e. if communication fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1Input filter
P1 = 0 input filter on, pulse suppression &le- 2 ms
P1 = 1 input filter off (basic setting)
P2Synchronous mode
P2 = 0 synchronous mode on
P2 = 1 synchronous mode off (basic setting)
P3not used
Соответствие промышленным стандартам
Соответствие директивам
EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 61000-6-4:2007, EN 50295:1999
Соответствие индустриальным стандартам
ШумозащищенностьEN 61000-6-2:2005, EN 50295:1999
Излучаемые помехиEN 61000-6-4:2007
InputEN 61131-2
Степень защиты корпусаCEI 70-1/EN 60529
Fieldbus standardEN 50295, IEC 62026-2
Условия окружающей среды
Рабочая температура окружающей среды-25 ... 70 °C (-13 ... 158 °F)
Температура хранения устройства-25 ... 85 °C (-13 ... 185 °F)
Физические/механические параметры
Стандарты защищенностиIP67
ПодключениеCable piercing method
flat cable yellow/flat cable black
inputs/outputs: M12 round connector
Материал
КорпусPBT
Масса200 g
MountingMounting base

Аксессуары и комплектующие

Совместимое оборудованиеНаименование
VBP-HH1-V3.0-KITAS-Interface Handheld with accessory
VAZ-PK-1,5M-V1-GConnection cable module/hand-held programming device
VAZ-V1-BBlind plug
VAZ-G12-MARK1-GNLettering set
VAZ-CLIP-G12AS-Interface accessories
Нет отзывов об этом товаре.

Написать отзыв о AS-Interface sensor/actuator module VBA-2E2A-G12-ZAJ/EA..

Ваше Имя:


Ваш отзыв:

Оценка: Плохо           Хорошо

Введите код, указанный на картинке: