Features |
| Switching frequency: | 5,000 Hz | |
| Connection type: | Cable, 2-wire, 2 m | |
| Switching output: | NAMUR | |
| Electrical wiring: | DC 2-wire | |
| Sensing face: | Front | |
Mechanics/electronics |
| Enclosure rating: | IP 67 1) | |
| Cylinder types: | Tie rod cylinder | |
| Supply voltage: | 5 V DC ... 25 V DC | |
| Repeatability: | ≤- 0.1 mm 2) | |
| EMC: | Nach EN 60947-5-6 | |
| Cable material: | PVC | |
| Conductor cross-section: | 0.34 mm? | |
| Reverse polarity protection: | Yes | |
| Short-circuit protection: | Yes | |
| Housing material: | Metal, Aluminum | |
| Sensing face material: | Plastic | |
| Time delay before availability: | ≤- 2 ms | |
| Ambient operating temperature: | -25 °C ... 70 °C | |
| Shock/vibration: | 30 g, 11 ms/10 ... 55 Hz, 1 mm | |
| Power-up pulse protection: | - | |
| Magnetic field sensitivity, min.: | 3 mT | |
| Hazardous area category: | 2G | |
| Temperature drift (% of Sr): | ± 0.005 mm/°C | |
| Power consumption, attenuated: | > 2.5 mA | |
| Power consumption, unattenuated: | ≤- 1 mA | |
| Input voltage Ui max.: | 16 V 3) | |
| Input power Pi max.: | 100 mW 4) | |
| Input current Ii max.: | 30 mA 5) | |
| Internal capacitance Ci max.: | 15 nF 6) | |
| Internal inductance Li max.: | ≤- 35 µH 7) | |
| Nominal voltage: | 8.2 V DC | |
| Cable resistance: | ≤- 50 Ω- | |
| EC Approval Certificate: | TUV 99 ATEX 1398 | |
| ATEX marking: | Ex II 2G EEx ib IIC T6 Ta: -20 °C ... 70 °C | |
| Dimensions (W x H x D): | 30 mm | |
*изображение на сайте может отличаться от реального