Features |
| Sensing range Sn: | 0 mm ... 10 mm | |
| Installation type: | Non-flush | |
| Switching frequency: | 25 Hz, 70 Hz 1) 2) | |
| Connection type: | Cable, 2-wire, 2 m | |
| Output function: | NC | |
| Electrical wiring: | AC/DC 2-wire | |
| Enclosure rating: | IP 67 3) | |
| Design: | Cylindrical | |
| Housing: | Standard | |
| Assured sensing range Sa: | 8.1 mm | |
| Diameter: | 20 mm | |
Mechanics/electronics |
| Housing length: | 77 mm | |
| Supply voltage: | 20 V AC/DC ... 250 V AC/DC | |
| Voltage drop: | ≤- 6 V (DC), ≤- 6.5 V (AC) | |
| Output current Ia: | ≤- 100 mA (DC), ≤- 250 mA (AC (+80 °C)), ≤- 350 mA (AC (+50 °C)) | |
| Hysteresis: | 1 % ... 15 % | |
| Temperature drift (% of Sr): | ± 10 % | |
| EMC: | According to EN 60947-5-2 As per EN 55011 class B | |
| Cable material: | PVC | |
| Conductor cross-section: | 0.5 mm? | |
| Cable diameter: | 5.6 mm | |
| Housing material: | Plastic | |
| Housing cap material: | Plastic, PBT | |
| Ambient operating temperature: | -25 °C ... 80 °C | |
| Shock/vibration: | 30 g, 11 ms/10 ... 55 Hz, 1 mm | |
| Off-state current: | ≤- 0.8 mA (DC 24 V), ≤- 1.3 mA (AC 110V), ≤- 2.5 mA (AC 250 V) | |
| Short-time withstand current: | 2.2 A 1) | |
| Output current: | 5 mA | |
*изображение на сайте может отличаться от реального