Features |
| Pressure type: | Absolute pressure | |
| Measuring range: | 0 bar ... 10 bar | |
| Process temperature: | -20 °C ... 85 °C | |
| CE-conformity: | Yes | |
| Display: | 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1000, 500, 200, 100 ms (adjustable), accuracy: ≤- 1.0 % of span ± 1 digit | |
| Output signal: | IO-Link, 2x PNP + 4...20 mA | |
| Rotatable housing: | Display against housing with electrical connection: 330°. Housing against process connection: 320° | |
Performance |
| Accuracy: | <= +/- 1 % (of span) | |
| Non-linearity: | <= +/- 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | |
| Setting accuracy of switching outputs: | ≤- ± 0,5 % of span | |
| Response time: | 3 ms | |
| Long-term drift/one-year stability: | ≤- 0.2 % of span | |
| Temperature coefficient in rated temperature range: | Mean TC of span: ≤- 0.2 % of span / 10 K, Mean TC of zero: ≤- 0.2% of span / 10 K | |
| Rated temperature range: | 0 °C ... 80 °C | |
Mechanics/electronics |
| Process connection: | G 1/4 A according to DIN 3852-E | |
| Wetted parts: | Pressure Connection: 316L, Pressure sensor: 316L (for measurement ranges from 0 bar ... 10 bar rel: 13-8 PH) | |
| Seal: | NBR | |
| Housing material: | Display window: PC, Plastic head: PC + ABS, Buttons: TPE-E, Lower body: 316L | |
| Enclosure rating: | IP 67 | |
| Connection type: | Plug M12 x 1, 5-pin, IP 67 | |
| Supply voltage: | 15 V DC ... 35 V DC | |
| Power consumption: | 100 mA | |
| Electrical safety: | Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M | |
| Protection class III: | Yes | |
| Weight sensor: | 200 g | |
| Service life: | 10 Mio. max. life cycles | |
| Total current consumption: | max. 350 mA / 600 mA (incl. switching current) | |
| Isolation voltage: | 500 V DC | |
| CE-conformity: | Pressure equipment directive: This instrument is a pressure accessory as defined by the directive 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 | |
Ambient data |
| Storage temperature: | -20 °C ... 80 °C | |
| Ambient temperature: | -20 °C ... 80 °C | |
| Shock load: | 50 g according to IEC 60068-2-27 (mechanical shock) | |
| Vibration load: | 10 g according to IEC 60068-2-6 (vibration under resonance) | |
| Relative humidity: | 90 % | |
*изображение на сайте может отличаться от реального