Features |
| Pressure type: | Absolute pressure | |
| Measuring range: | 0 bar ... 1.6 bar | |
| Process temperature: | -20 °C ... 85 °C | |
| Rated temperature: | 0 °C ... 80 °C | |
| CE-conformity: | Yes | |
| Display: | 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1000, 500, 200, 100 ms (adjustable), Accuracy: &le- 1.0 % of span ± 1 digit | |
| Output signal: | 2x PNP + 4...20 mA | |
Performance |
| Accuracy: | <= +/- 1 % (of span) | |
| Non-linearity: | 0.5 % (Best Fit Straight Line (BFSL)) | |
Mechanics/electronics |
| Process connection: | G 1/2 B (EN 837) | |
| Wetted parts: | Pressure Connection: 316L, Pressure sensor: 316 L (for measurement ranges from 0 ... 10 bar rel: 13-8 PH) | |
| Seal: | Stainless steel | |
| Housing material: | Display window: PC, Plastic head: PC + ABS, Buttons: TPE-E, Lower body: 316 L | |
| Enclosure rating: | IP 67 | |
| Connection type: | Plug M12 x1, 5-pin | |
| Supply voltage: | 15 V DC ... 35 V DC | |
| Power consumption: | 100 mA | |
| Electrical safety: | Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M | |
| Protection class III: | Yes | |
Ambient data |
| Ambient temperature: | -20 °C ... 80 °C | |
| Shock load: | 50 g according to IEC 60068-2-27 (mechanical shock) | |
| Vibration load: | 10 g according to IEC 60068-2-6 (vibration under resonance) | |
*изображение на сайте может отличаться от реального