Features |
| Pressure type: | Compound pressure | |
| Measuring range: | -1 bar ... 9 bar | |
| Process temperature: | -30 °C ... 100 °C | |
| CE-conformity: | Yes | |
| Output signal: | 4...20 mA | |
Performance |
| Accuracy: | <= +/- 0.5 % (of span) | |
| Non-linearity: | <= +/- 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | |
| Long-term drift/one-year stability: | <= +/- 0.2 % of span (at reference conditions) | |
| Temperature coefficient in rated temperature range: | Mean TC of span ≤- 0.2 % of span / 10 K, Mean TC of zero: ≤- 0.2 % of span / 10 K (< 0.4 % for pressure ranges ≤- 0.25 bar) | |
| Rated temperature range: | 0 °C ... 80 °C | |
| Non-repeatability: | <= +/- 0.1 % of span | |
| Response time (10 % ... 90 %): | ≤- 1 ms (≤- 10 ms at medium temperatures below < -30°C for pressure ranges up to 25 bar or with flush-mounted membrane) | |
Mechanics/electronics |
| Process connection: | G 1/4 A according to DIN 3852-E | |
| Wetted parts: | Standard: Stainless steel | |
| Seal: | Without sealing | |
| Pressure port: | Standard | |
| Housing material: | Stainless steel | |
| Enclosure rating: | IP 67 | |
| Connection type: | M12 x 1, 4-pin, IP 67 | |
| Supply voltage: | 10 V DC ... 30 V DC | |
| Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | |
| Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | |
| Protection class III: | Yes | |
| Weight sensor: | 200 g | |
| CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 | |
Ambient data |
| Storage temperature: | -40 °C ... 100 °C | |
| Ambient temperature: | -20 °C ... 80 °C | |
| Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) | |
| Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) | |
*изображение на сайте может отличаться от реального