Gas Analyzers | |||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||
Technical data | |||
Measuring principle: | Flame ionisation detection | ||
Number of measuring components: | 1 | ||
TUV-approved measurand: | Corg | ||
Measuring ranges: | Corg: 0 ... 10 ppm / 0 ... 100 Vol.-% | ||
Sample quantity: | 40 ... 80 l/h depending on sample gas pressure | ||
Process temperature: | Inline type: 0 ... 350 °C, Other types: 0 ... 200 °C | ||
Process pressure: | 50 ... 50 hPa relative | ||
Ambient temperature: | Analyzer, terminal box: 0 ... 55 °C, Operating unit: 0 ... 40 °C | ||
Ambient humidity: | 0 ... 90 % relative humidity | ||
Conformities: | 2000/76/EC, 2001/80/EC, EN 14181, GOST, MCERTS, German Clean Air Regulations, U.S. EPA compliant | ||
Remark: | Measuring ranges related to propane, Six measuring ranges switchable | ||
Ex-approvals ATEX: | Ex-type Zone 1: II 2 G EEx p IIB+H2 T=170...220 °C suites also for hazardous area Zone 2 | ||
Electrical safety: | CE, EMC, LVD | ||
Enclosure rating: | 19''-rack, wall mounting enclosure, control unit: IP 20, Inline type: IP 65 | ||
Analogue outputs: | 2 outputs: 0/4 ... 20 mA, 500 Ω- floating | ||
Analogue inputs: | 4 inputs , 0.25 ... 20 V assignment depending on system | ||
Digital outputs: | 8 tansistor switches: 24 V AC/DC, 100 mA floating- for status signals ok, failure, calibration, maintenance request and alarms | ||
Digital inputs: | 3 inputs 24 V DC ±10 %, floating, triggerable | ||
Interfaces: | RS-232c (option) floating- for printer, I/O-box, remote control, fieldbus | ||
Operation: | Menu-driven operation via separate control unit | ||
Device types: | 19''-rack, Type for Ex-zone 1, Inline type, Wall mounting enclosure | ||
System components: | Analyzer, Operating unit, Terminal box | ||
Note: | The scope of delivery depends on application and customer specifications. |