Applications |
| Access protection (vertical): | Yes | |
| Access protection with muting: | - | |
| Hazardous area protection (horizontal): | - | |
Functions-Sender/receiver in one housing |
| System construction: | Active/passive system | |
| Restart interlock: | Yes | |
| Restart interlock (delivery status): | Internal | |
| External device monitoring: | Yes | |
| External device monitoring (delivery status): | Activated | |
| Beam coding: | Yes | |
| Beam coding (delivery status): | Non-coded | |
| Muting with: | Flexi Classic | |
| Configurable application diagnostic output: | Yes | |
| Application diagnostic output (delivery status): | Contamination (OWS) | |
| Configurable scanning range: | Yes | |
| Scanning range (delivery status): | 4.5 m | |
| Integrated laser alignment aid: | - | |
| End cap with integrated LED: | Yes | |
| Additional reset connection: | Yes | |
| SDL interface: | - | |
| Configuration method: | configuration buttons | |
| Sender test: | - | |
| Safe device communication via EFI/SDL: | - | |
Technical Data-Sender/receiver in one housing |
| Number of beams: | 2 | |
| Scanning range from ... to: | 4.5 m ... , configurable | |
| Scanning range High Range: | 0.5 m ... 4.5 m | |
| Type: | Type 4 (IEC 61496) | |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) | |
| Category: | category 4 (EN ISO 13849) | |
| Performance level: | PL e (EN ISO 13849) | |
| PFHd: | 6.6 * 1E-09 | |
| TM (mission time): | 20 a | |
| Housing cross-section: | 52 mm x 55.5 mm | |
| Maximum response time: | 10 ms | |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | |
| Power consumption: | ≤- 0.6 A | |
| Type of output: | Safety outputs (OSSD) | |
| Display elements: | LED/7-segment | |
| Maximum switching voltage: | UV - 2,25 V | |
| Maximum switching current: | 500 mA | |
| Protection class: | III (EN 50178:1998) | |
| Enclosure rating: | IP 65 (EN 60529) | |
| System connection: | plug | |
| Ambient operating temperature from ... to: | -10 °C ... 55 °C | |
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) | |
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | |
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) | |
| Resolution: | 500 mm | |
| Scanning range from ... to (delivery status): | ≥- 4.5 m | |