Applications |
| Hazardous area protection (vertical): | Yes | |
| Access protection (vertical): | Yes | |
| Hazardous area protection (horizontal): | Yes | |
Functions |
| Static control outputs for switching between warning fields: | Yes | |
| Incremental encoder inputs: | - | |
| External device monitoring: | - | |
| Integrated configuration memory: | - | |
| Expanded measured data output (CMS, RS-422): | - | |
| Measured data output (RS-422): | - | |
| Safe device communication via EFI/SDL: | Yes | |
Technical data |
| Laser protection class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) | |
| Enclosure rating: | IP 65 (EN 60529) | |
| Protection class: | III (EN 50178) | |
| Type: | Type 3 (EN 61496-1) | |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) | |
| Category: | Category 3 (EN ISO 13849) | |
| Performance level: | PL d (EN ISO 13849) | |
| PFHd: | 8.0 * 1E-08 (EN ISO 13849) | |
| TM (mission time): | 20 a (EN ISO 13849) | |
| Ambient operating temperature from ... to: | -10 °C ... 50 °C | |
| Dimensions (W x H x D): | 102 mm x 116 mm x 105 mm | |
| Weight: | 0.8 kg, without connecting cables | |
| Scan angle: | 270 ° | |
| Protective field range: | 2 m | |
| Maximum warning field range: | 8 m | |
| Number of field sets: | 16 1) | |
| Response time: | 80 ms | |
| Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, selectable | |
| Distance measuring range: | 30 m | |
| Number of multiple samplings: | Configurable via CDS 2 ... 16 | |
| Electrical connection: | Connecting cable with round plug connector | |
| Supply voltage: | 16.8 V DC, 24 V DC, 30 V DC | |
| Number of static control inputs with EFI: | 5 2) | |
| Number of stand-by inputs: | 1 3) | |
| Number of outputs: | Depends on the configuration of the connected EFI device | |
| Configuration and diagnostics interface: | RS-232 | |