S3000 PROFINET IO Professional, Sensor head with I/O module Sick S30A-4111DP (1045651)

S3000 PROFINET IO Professional, Sensor head with I/O module Sick S30A-4111DP (1045651)
Производитель: Sick
Артикул: 1045651
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
Safety laser scanners
S3000 PROFINET IO Professional, Sensor head with I/O module
 
Model NameS30A-4111DP
Part No.1045651
 

Самое главное

  • Direct integration in PROFINET IO safe bus system
  • 4 m protective field range
  • 8 switchable field sets (8 protective fields, 8 warning fields)
  • Remote diagnostics and configuration through safety controller
  • Managed 2-port switch for RJ45 plug connector
  • Configuration memory integrated in the system plug
  • Simultaneous monitoring of two protective fields

    Преимущества

  • Reliable, fault-tolerant communication with PLC controller using state-of-the-art fiber-optic technology.
  • Efficient, cost-effective protection - networked through direct connection to PROFINET IO networks
  • Rapid diagnosis by means of remote access prevents downtimes
  • Standardized integration in PLC controllers, thanks to GSDML generic station description
  • Largest protective field range available in the market increases the variety of application possibilities
  • Quick recommissioning via configuration memory
  • Easy installation, commissioning and maintenance for stationary and mobile applications
  • Decades of proven safety technology guarantee maximum reliability and availability - even under difficult conditions
     
     
       

    Applications
    Hazardous area protection (vertical):Yes
    Access protection (vertical):Yes
    Hazardous area protection (horizontal):Yes


    Functions
    Simultaneous monitoring of two areas:Yes
    Static control outputs for switching between warning fields:-
    Incremental encoder inputs:-
    External device monitoring:-
    Integrated configuration memory:Yes
    Expanded measured data output (CMS, RS-422):-
    Measured data output (RS-422):-
    Safe device communication via EFI/SDL:-


    Technical data
    Laser protection class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
    Enclosure rating:IP 65 (EN 60529)
    Protection class:III (EN 50178)
    Type:Type 3 (IEC/EN 61496-3)
    Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
    Category:Category 3 (EN ISO 13849)
    Performance level:PL d (EN ISO 13849)
    PFHd:8.0 * 1E-08 (EN ISO 13849)
    TM (mission time):20 a (EN ISO 13849)
    Ambient operating temperature from ... to:-10 °C ... 50 °C
    Dimensions (W x H x D):155 mm x 185 mm x 160 mm
    Weight:3.3 kg
    Scan angle:190 °
    Protective field range:4 m
    Maximum warning field range:49 m
    Number of field sets:8 1)
    Response time:60 ms, 120 ms 2)
    Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, selectable
    Distance measuring range:49 m
    Number of multiple samplings:Configurable via CDS 2 ... 16
    Electrical connection:Copper conductor (2 sockets for RJ-45 push-pull plug), plug-in supply connector with screw type terminal and cable gland for cable diameter 5 mm ... 10 mm
    Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
    Configuration and diagnostics interface:RS-232
    Supported services:Acyclic read write services for communication via TCI interface, LLDP, MIB II, PROFINET IO Conformance Class B, SNMP, TCP/IP communication via Port 9000
    1) 1 field set = 1 protective field and 2 warning fields  2) Depending on basic response time and multiple sampling  



    *изображение на сайте может отличаться от реального
    Нет отзывов об этом товаре.

    Написать отзыв о S3000 PROFINET IO Professional, Sensor head with I/O module ..

    Ваше Имя:


    Ваш отзыв:

    Оценка: Плохо           Хорошо

    Введите код, указанный на картинке: