Functions |
| Restart interlock: | - | |
| External device monitoring: | - | |
| Beam coding: | Yes | |
| Beam coding (delivery status): | Non-coded | |
| Muting with: | Flexi Classic | |
| Extension connection: | Yes | |
| Emergency stop / bypass at extension connection: | - | |
| Bypass (with UE402): | - | |
| Operating mode switching (with UE402): | - | |
| PSDI mode with: | UE470 | |
| Type of blanking: | 1 beam floating blanking, 2 beam floating blanking | |
| Type of blanking (delivery status): | deactivated | |
| Reduced resolution: | - | |
| Configurable scanning range: | Yes | |
| Integrated laser alignment aid: | Yes | |
| Configuration method: | DIP switch | |
| Safe device communication via EFI/SDL: | - | |
| End cap with integrated LED: | - | |
| Configuration of the extended I/O: | deactivated | |
Technical data |
| Protective field height: | 900 mm | |
| Resolution: | 30 mm | |
| Scanning range Low Range: | 0 m ... 6 m | |
| Scanning range High Range: | 5 m ... 19 m | |
| Housing length: | 1,040 mm | |
| Housing cross-section: | 52 mm x 55.5 mm | |
| Type: | Type 4 (IEC 61496) | |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (EN 62061) | |
| Category: | Category 4 (EN ISO 13849) | |
| Performance level: | PL e (EN ISO 13849) | |
| PFHd: | 3.2 * 1E-08 | |
| TM (mission time): | 20 a | |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | |
| Maximum power consumption: | 13.8 W | |
| Wave length: | 950 nm | |
| Protection class: | III (EN 50178:1998) | |
| Enclosure rating: | IP 65 | |
| Ambient operating temperature from ... to: | 0 °C ... 55 °C | |
| Connection type: | Plug M12 x 5 | |
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) | |
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | |
| Shock resistance: | 10 g, 16 ms, IEC 60068-2-29 | |
| Connection type extension connection: | Socket M12 x 5 | |
| Cable length extension connection: | 10 m | |
| Scanning range from ... to (delivery status): | 0 m ... 6 m | |
| Response time: | 12 ms (without beam coding, without blanking, no cascaded systems. Other response times see operating instructions.) | |
| Maximum switching current: | 500 mA | |