C2000 RES/EDM Sick (1042140)

C2000 RES/EDM Sick (1042140)
Производитель: Sick
Артикул: 1042140
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
Safety light curtains
C2000 RES/EDM
 
Receiver
Model NameC20E-060302A31
Part No.1042140
 
Sender
Model NameC20S-060102A11
Part No.1016574
 

Самое главное

  • Approved 7-segment display for diagnostics
  • Robust housing with an industrial design
  • Impact and scratch-resistant front screen
  • Standardized and a wide range of connection and mounting accessories
  • External device monitoring (EDM) and restart interlock (RES)
  • Internal self-testing function, configurable without PC
  • Beam coding for correct system allocation

    Преимущества

  • Customer-friendly interfaces and status display facilitate commissioning and maintenance
  • High-quality industrial design for reliable and durable continuous operation
  • 7-segment display saves time during alignment and diagnostics
  • High level of resistance and robust design for high machine availability, even under special ambient conditions
  • A multitude of intelligent mounting adapters enables flexible installation
  • Integrated additional functions: Reset and EDM for short cable distances to connect with cost-optimized, positively guided relays
     
     
         
     
     
     

    Functions-Sender
    Beam coding:Yes
    Configuration method:hard wired
    Extension connection:-
    Safe device communication via EFI/SDL:-


    Functions-Receiver
    Restart interlock:Yes
    External device monitoring:Yes
    Beam coding:-
    Muting with:Flexi Classic, Flexi Soft
    Configuration method:hard wired
    Extension connection:-
    Safe device communication via EFI/SDL:-


    Technical Data-Sender
    Protective field height:600 mm
    Resolution:20 mm
    Scanning range from ... to:0 m ... 6 m
    Housing cross-section:34 mm x 29 mm
    Type:Type 2 (IEC 61496)
    Safety integrity level:SIL2 (IEC 61508), SILCL2 (IEC 62061)
    Category:category 2 (EN ISO 13849)
    Test rate (internal test):13 /s (EN ISO 13849)
    Maximum demand rate:8 /min (EN ISO 13849) 1)
    Performance level:PL d (EN ISO 13849)
    PFHd:2.2 * 1E-08
    TM (mission time):20 a
    Enclosure rating:IP 65 (EN 60529)
    Protection class:III
    Ambient operating temperature from ... to:0 °C ... 55 °C
    Vibration resistance (checked to):5 g (IEC 68-2-6)
    Oscillation frequency from ... to:10 Hz ... 55 Hz
    Shock resistance:10 g, 16 ms (IEC 68-2-29)
    Weight:0.65 kg
    Supply voltage typical, from, to:24 V DC, 19.2 V DC, 28.8 V DC
    Maximum power consumption:6.2 W
    Wave length:950 nm
    System connection:plug M12 x 8
    Maximum connection cable cross-section:0.25 mm?
    1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.  


    Technical Data-Receiver
    Protective field height:600 mm
    Resolution:20 mm
    Housing cross-section:34 mm x 29 mm
    Type:Type 2 (IEC 61496)
    Safety integrity level:SIL2 (IEC 61508), SILCL2 (IEC 62061)
    Category:category 2 (EN ISO 13849)
    Test rate (internal test):13 /s (EN ISO 13849)
    Maximum demand rate:8 /min (EN ISO 13849) 1)
    Performance level:PL d (EN ISO 13849)
    PFHd:2.2 * 1E-08
    TM (mission time):20 a
    Enclosure rating:IP 65 (EN 60529)
    Protection class:III
    Ambient operating temperature from ... to:0 °C ... 55 °C
    Vibration resistance (checked to):5 g (IEC 68-2-6)
    Oscillation frequency from ... to:10 Hz ... 55 Hz
    Shock resistance:10 g, 16 ms (IEC 68-2-29)
    Weight:0.65 kg
    Response time:18 ms
    Supply voltage typical, from, to:24 V DC, 19.2 V DC, 28.8 V DC
    Maximum power consumption:8 W
    Maximum switching voltage:min. VS - 2.25 V DC
    Maximum switching current:500 mA
    Wave length:950 nm
    System connection:plug M12 x 8
    Maximum connection cable cross-section:0.25 mm?
    1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.  

    *изображение на сайте может отличаться от реального