Functions-Sender |
| Beam coding: | Yes | |
| Reduced resolution: | - | |
| Configuration method: | PC with CDS (Configuration and Diagnostic Software) | |
| Extension connection: | - | |
| PSDI mode with: | UE402 | |
| Safe device communication via EFI/SDL: | Yes | |
Functions-Receiver |
| Restart interlock: | Yes | |
| Restart interlock (delivery status): | External | |
| External device monitoring: | Yes | |
| External device monitoring (delivery status): | Selected | |
| Beam coding: | Yes | |
| Beam coding (delivery status): | Non-coded | |
| Reduced resolution: | - | |
| Bypass (with UE402): | Yes | |
| Emergency stop / bypass at extension connection: | - | |
| Operating mode switching (with UE402): | Yes | |
| PSDI mode with: | UE402 | |
| Muting with: | Flexi Classic | |
| Configuration method: | PC with CDS (Configuration and Diagnostic Software) | |
| Extension connection: | - | |
| Safe device communication via EFI/SDL: | Yes | |
Technical Data-Sender |
| Protective field height: | 300 mm | |
| Resolution: | 30 mm | |
| Housing length: | 427 mm | |
| Housing cross-section: | 48 mm x 40 mm | |
| Type: | Type 4 (IEC 61496) | |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) | |
| Category: | category 4 (EN ISO 13849) | |
| Performance level: | PL e (EN ISO 13849) | |
| PFHd: | 1.5 * 1E-08 | |
| TM (mission time): | 20 a | |
| Enclosure rating: | IP 65 | |
| Protection class: | III | |
| Ambient operating temperature from ... to: | 0 °C ... 55 °C | |
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) | |
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | |
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) | |
| Weight: | 820 g | |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | |
| Wave length: | 950 nm | |
| Connection type: | Hirschmann plug M26 x 11 + FE, straight | |
| Connection type configuration connection: | M8 x 4 | |
| Maximum connection cable cross-section: | 0.75 mm? | |
Technical Data-Receiver |
| Protective field height: | 300 mm | |
| Resolution: | 30 mm | |
| Scanning range from ... to: | 0 m ... 19 m | |
| Scanning range from ... to (delivery status): | 0 m ... 6 m | |
| Housing length: | 427 mm | |
| Housing cross-section: | 48 mm x 40 mm | |
| Type: | Type 4 (IEC 61496) | |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) | |
| Category: | category 4 (EN ISO 13849) | |
| Performance level: | PL e (EN ISO 13849) | |
| PFHd: | 1.5 * 1E-08 | |
| TM (mission time): | 20 a | |
| Enclosure rating: | IP 65 | |
| Protection class: | III | |
| Ambient operating temperature from ... to: | 0 °C ... 55 °C | |
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) | |
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | |
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) | |
| Weight: | 850 g | |
| Response time without beam coding: | ≤- 10 ms | |
| Response time with beam coding: | ≤- 12 ms | |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | |
| Maximum switching current: | 500 mA | |
| Wave length: | 950 nm | |
| Connection type: | Hirschmann plug M26 x 11 + FE, straight | |
| Connection type configuration connection: | M8 x 4 | |
| Maximum connection cable cross-section: | 0.75 mm? | |
*изображение на сайте может отличаться от реального