Applications |
| Hazardous area protection (vertical): | - | |
| Access protection (vertical): | - | |
| Hazardous area protection (horizontal): | Yes | |
Functions |
| Simultaneous monitoring of two areas: | - | |
| Static control outputs for switching between warning fields: | - | |
| Incremental encoder inputs: | - | |
| External device monitoring: | - | |
| Reflector mark detection: | - | |
| Expanded measured data output: | - | |
Technical data |
| Laser protection class: | 1 | |
| Enclosure rating: | IP 65 (EN 60529) | |
| Protection class: | 2 (totally isolated) | |
| Type: | Type 3 (IEC/EN 61496-1) | |
| Ambient operating temperature from ... to: | 0 °C ... 50 °C | |
| Dimensions (W x H x D): | 155 mm x 185 mm x 156 mm | |
| Weight: | 4.5 kg | |
| Maximum warning field range: | 50 m | |
| Response time: | > 80 ms | |
| Resolution: | < 50 mm | |
| Distance measuring range: | 49 m | |
| Number of multiple samplings: | 2 ... 16 | |
| Electrical connection: | Plug-in connection box with cable fitting, Crimp contacts | |
| Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC | |
| Number of warning field outputs: | 1 | |
| Maximum output current: | 150 mA | |
| Data interface: | RS-232/RS-422 | |
*изображение на сайте может отличаться от реального