Functions-Sender |
| Beam coding: | Yes | |
| Configuration method: | hard wired | |
| Extension connection: | Yes | |
| Safe device communication via EFI/SDL: | - | |
Functions-Receiver |
| Restart interlock: | - | |
| External device monitoring: | Yes | |
| Beam coding: | Yes | |
| Muting with: | Flexi Classic, Flexi Soft | |
| Configuration method: | hard wired | |
| Extension connection: | Yes | |
| Safe device communication via EFI/SDL: | - | |
Technical Data-Sender |
| Protective field height: | 450 mm | |
| Resolution: | 30 mm | |
| Scanning range from ... to: | 0 m ... 6 m | |
| Housing cross-section: | 34 mm x 29 mm | |
| Type: | Type 2 (IEC 61496) | |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (IEC 62061) | |
| Category: | category 2 (EN ISO 13849) | |
| Test rate (internal test): | 13 /s (EN ISO 13849) | |
| Maximum demand rate: | 8 /min (EN ISO 13849) 1) | |
| Performance level: | PL d (EN ISO 13849) | |
| PFHd: | 2.2 * 1E-08 | |
| TM (mission time): | 20 a | |
| Enclosure rating: | IP 65 (EN 60529) | |
| Protection class: | III | |
| Ambient operating temperature from ... to: | 0 °C ... 55 °C | |
| Vibration resistance (checked to): | 5 g (IEC 68-2-6) | |
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | |
| Shock resistance: | 10 g, 16 ms (IEC 68-2-29) | |
| Weight: | 0.51 kg | |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | |
| Maximum power consumption: | 6.2 W | |
| Wave length: | 950 nm | |
| Connection type: | plug M12 x 8 | |
| Connection type extension connection: | plug M12 x 8 | |
| Maximum connection cable cross-section: | 0.25 mm? | |
Technical Data-Receiver |
| Protective field height: | 450 mm | |
| Resolution: | 30 mm | |
| Housing cross-section: | 34 mm x 29 mm | |
| Type: | Type 2 (IEC 61496) | |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (IEC 62061) | |
| Category: | category 2 (EN ISO 13849) | |
| Test rate (internal test): | 13 /s (EN ISO 13849) | |
| Maximum demand rate: | 8 /min (EN ISO 13849) 1) | |
| Performance level: | PL d (EN ISO 13849) | |
| PFHd: | 2.2 * 1E-08 | |
| TM (mission time): | 20 a | |
| Enclosure rating: | IP 65 (EN 60529) | |
| Protection class: | III | |
| Ambient operating temperature from ... to: | 0 °C ... 55 °C | |
| Vibration resistance (checked to): | 5 g (IEC 68-2-6) | |
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | |
| Shock resistance: | 10 g, 16 ms (IEC 68-2-29) | |
| Weight: | 0.51 kg | |
| Response time: | 8.5 ms | |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | |
| Maximum power consumption: | 8 W | |
| Maximum switching voltage: | min. VS - 2.25 V DC | |
| Maximum switching current: | 500 mA | |
| Wave length: | 950 nm | |
| Connection type: | plug M12 x 8 | |
| Connection type extension connection: | plug M12 x 8 | |
| Maximum connection cable cross-section: | 0.25 mm? | |
*изображение на сайте может отличаться от реального