Ничего не куплено!
Transponder safety switches | |||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||
Technical data | |||
Sensor principle: | Transponder | ||
Coding: | Multicoded | ||
Safety integrity level: | SILCL3 (EN 62061) | ||
Category: | Category 4 (EN ISO 13849) | ||
Performance level: | PL e (EN ISO 13849) | ||
PFHd: | 2.1 * 1E-09 (EN ISO 13849) | ||
TM (mission time): | 20 a (EN ISO 13849) | ||
Classification in compliance with IEC/EN 60947-5-3: | PDF-M | ||
Housing material: | Plastic | ||
Enclosure rating: | IP 67 | ||
Protection class: | III | ||
Ambient operating temperature from ... to: | -20 °C ... 55 °C | ||
Connection type: | Connector | ||
Size of the cable gland: | M12 | ||
Type of output: | Semiconductor (OSSD) | ||
Number of safe outputs: | 2 | ||
Response time: | 290 ms | ||
Supply voltage typical, from, to: | 24 V DC, 20.4 V DC, 27.6 V DC | ||
Rated operating current (voltage): | 0.4 A (24 V DC) | ||
Safe switch on distance Sao: | 15 mm, with actuator T4000-1KBA 18 mm, with actuator T4000-1KBQ 19 mm, with actuator T4000-1KBR | ||
Status display: | Yes | ||
Weight: | 0.4 kg |