Flexi Classic Muting main unit Sick UE410-MM3 (6034482)

Flexi Classic Muting main unit Sick UE410-MM3 (6034482)
Производитель: Sick
Артикул: 6034482
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
Safety controllers
Flexi Classic Muting main unit
 
Model NameUE410-MM3
Part No.6034482
 

at a glance

  • Two variants to choose from: main module for common applications or an expert module for muting
  • Central processing unit
  • Modularly expandable
  • 6 inputs, 4 outputs
  • Small width of 22.5 mm
  • Pluggable terminals for a fast module replacement
  • PNP outputs, each up to 2A

    Преимущества

  • One module offers complete functionality of inputs and outputs up to the logic
  • Easy to expand if more inputs and outputs are required
  • Easy diagnostics via clear LED status indicators, which reduces downtime
  • Use of powerful PNP semiconductor outputs allows to remove relays
     
     
       

    Applications
    Emergency stop pushbuttons:-
    Opto-electronic protective devices:Yes
    Non-contact safety switches:Yes
    Two-hand control systems:-
    Testable inductive sensors:-
    Electro-mechanical safety switches:-


    Functions
    Number of reset-/restart inputs:1
    Number of external device monitoring:1
    Muting:Yes
    Override:Yes
    Belt stop:-
    Concurrence monitoring:Yes
    Monitoring total muting time:Yes
    Sensor gap monitoring:Yes
    End of muting by ESPE:Yes
    Logical functions:Muting, override
    Safe device communication via EFI/SDL:-


    Electrical data
    Supply voltage:24 V DC (19.2 V DC ... 30 V DC)
    Type of supply voltage:PELV (electrical output circuit on UE410-4RO/UE410-2RO > 25 V AC/60 V DC), PELV or SELV (electrical output circuit on UE410-4RO/UE410-2RO < 25 V AC/60 V DC)
    Power consumption:3 W
    Residual ripple:≤- 3 V
    Switch-on time:10 s
    Short-circuit protection:4 A gG
    Number of inputs:1 dual-channel and 4 single-channel
    Input voltage HIGH:15 V DC ... 30 V DC
    Input voltage LOW:-5 V DC ... 5 V DC
    Input current HIGH:2.3 mA ... 3 mA3.6 mA
    Input current LOW:-2.5 mA ... 0.15 mA
    Switch-on time of inputs:70 ms
    Number of muting sensors:2, 4
    Muting time to operate:70 ms
    Tolerated muting sensor signal interrupt:200 ms 1)
    Total muting monitoring time:Activation and time adjustable 0.33 ... 60 min
    Switch-on time ENTER button:3 s Upon applying the supply voltage
    Number of outputs:1 dual-channel and 2 single-channel
    Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
    Output voltage:18 V DC ... 30 V DC
    Output current:2 A
    Response time:< 13 ms
    1) One muting input may be LOW for this time  


    Ambient data
    Protection class standard:EN/IEC 60529
    Enclosure rating terminals:IP 20
    Vibration resistance:5 g, 5 Hz ... 500 Hz (EN 60068-2-6)
    Ambient operating temperature:-25 °C ... 55 °C
    Storage temperature:-25 °C ... 70 °C
    Air humidity:15 % ... 95 %, non-condensing
    Climate conditions according to:EN 61131-2
    Electromagnetic compatibility (EMC):EN 61000
    EN 55011
    Connection type:Cable gland
    Connection type:Plug-in screw type terminal
    Dimensions (W x H x D):29 mm x 96.5 mm x 120.8 mm
    Weight:180 g
    Protection class according to IEC 60529::IP 40


    Safety-related parameters
    Safety integrity level:SIL3 (IEC 61508), SILCL3 (IEC 62061)
    Category:Category 4 (EN ISO 13849)
    Performance level:PL e (EN ISO 13849)
    PFHd:7.9 * 1E-09
    TM (mission time):20 a



    *изображение на сайте может отличаться от реального
    Нет отзывов об этом товаре.

    Написать отзыв о Flexi Classic Muting main unit Sick UE410-MM3 (6034482)

    Ваше Имя:


    Ваш отзыв:

    Оценка: Плохо           Хорошо

    Введите код, указанный на картинке: