Functions |
| Muting: | - | |
| Override: | - | |
| Belt stop: | - | |
| Concurrence monitoring: | - | |
| Monitoring total muting time: | - | |
| Sensor gap monitoring: | - | |
| End of muting by ESPE: | - | |
| Safe device communication via EFI/SDL: | - | |
Electrical data |
| Power consumption: | 3 W | |
| Number of inputs: | 4 dual-channel or 8 single-channel | |
| Input voltage HIGH: | 13 V DC ... 30 V DC | |
| Input voltage LOW: | -5 V ... 5 V DC | |
| Input current HIGH: | 2.4 mA ... 3.8 mA | |
| Input current LOW: | -2.5 mA ... 2.1 mA | |
| Switch-on time of inputs: | 70 ms | |
| Synchronous time monitoring: | 1,500 ms (at program 3 and 5) | |
| Response time: | 17 ms ... 56 ms 1) | |
Ambient data |
| Protection class standard: | EN/IEC 60529 | |
| Enclosure rating terminals: | IP 20 | |
| Vibration resistance: | 5 g, 5 Hz ... 500 Hz (EN 60068-2-6) | |
| Ambient operating temperature: | -25 °C ... 55 °C | |
| Storage temperature: | -25 °C ... 70 °C | |
| Air humidity: | 15 % ... 95 %, non-condensing | |
| Climate conditions according to: | EN 61131-2 | |
| Electromagnetic compatibility (EMC): | EN 61000 EN 55011 | |
| Connection type: | Cable gland | |
| Connection type: | Plug-in spring terminals | |
| Dimensions (W x H x D): | 22.5 mm x 96.5 mm x 120.8 mm | |
| Weight: | 150 g | |
| Protection class according to IEC 60529:: | IP 40 | |
Safety-related parameters |
| Safety integrity level: | SILCL3 (IEC 62061) | |
| Category: | Category 4 (EN ISO 13849) | |
| Performance level: | PL e (EN ISO 13849) | |
| PFHd: | 3.8 * 1E-09 7.3 * 1E-09 | |
| TM (mission time): | 20 a | |
*изображение на сайте может отличаться от реального