Flexi Classic Expansion unit Sick UE410-XU3T50 (6032471)

Flexi Classic Expansion unit Sick UE410-XU3T50 (6032471)
Производитель: Sick
Артикул: 6032471
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
Safety controllers
Flexi Classic Expansion unit
 
Model NameUE410-XU3T50
Part No.6032471
 

at a glance

  • Two different types: in-/output expansion modules and input expansion modules
  • Two variants per type : module for common applications and an expert module for muting
  • Modularly expandable
  • 6 inputs, 4 outputs or 8 inputs
  • Small width of 22.5 mm
  • Pluggable terminals for a fast module replacement
  • PNP outputs, each up to 2A

    Преимущества

  • Only one configuration for the complete system, simplifying commissioning
  • Rich diagnostic functions available via Fieldbus gateway module
  • Easy to expand if more inputs are required
  • Easy diagnostics via clear LED status indicators
  • Use of powerful PNP semiconductor outputs allows to remove relays
     
     
       

    Applications
    Emergency stop pushbuttons:Yes
    Opto-electronic protective devices:Yes
    Non-contact safety switches:Yes
    Two-hand control systems:Yes
    Testable inductive sensors:Yes
    Electro-mechanical safety switches:Yes


    Functions
    Number of reset-/restart inputs:2
    Number of external device monitoring:2
    Muting:Yes
    Logical functions:OR, AND, BYPASS, Muting
    Safe device communication via EFI/SDL:-


    Electrical data
    Supply voltage:24 V DC (19.2 V DC ... 30 V DC)
    Type of supply voltage:PELV (electrical output circuit on UE410-4RO/UE410-2RO > 25 V AC/60 V DC), PELV or SELV (electrical output circuit on UE410-4RO/UE410-2RO < 25 V AC/60 V DC)
    Power consumption:3 W
    Residual ripple:≤- 3 V
    Switch-on time:60 s
    Short-circuit protection:4 A gG
    Number of inputs:2 dual-channel or 4 single-channel
    Input voltage HIGH:13 V DC ... 30 V DC
    Input voltage LOW:-5 V DC ... 5 V DC
    Input current HIGH:2.4 mA ... 3.8 mA
    Input current LOW:-2.5 mA ... 2.1 mA
    Switch-on time of inputs:70 ms
    Synchronous time monitoring:1,500 ms (at program 2), 500 ms (at program 4 and 5)
    Number of muting sensors:0, 2
    Muting time to operate:61 ms, at program 3 1)
    Tolerated muting sensor signal interrupt:100 ms, at program 3 2)
    Number of outputs:2 dual-channel or 4 single-channel
    Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
    Output voltage:18 V DC ... 30 V DC
    Output current:2 A
    Response time:13 ms ... 79 ms 3)
    1) Time between valid muting condition and active muting  2) One muting input may be LOW for this time  3) Depending on the selected program and the connected sensors  


    Ambient data
    Protection class standard:EN/IEC 60529
    Enclosure rating terminals:IP 20
    Vibration resistance:5 g, 5 Hz ... 500 Hz (EN 60068-2-6)
    Ambient operating temperature:-25 °C ... 55 °C
    Storage temperature:-25 °C ... 70 °C
    Air humidity:15 % ... 95 %, non-condensing
    Climate conditions according to:EN 61131-2
    Electromagnetic compatibility (EMC):EN 61000
    EN 55011
    Connection type:Cable gland
    Connection type:Plug-in screw type terminal
    Dimensions (W x H x D):22.5 mm x 96.5 mm x 120.8 mm
    Weight:180 g
    Protection class according to IEC 60529::IP 40


    Safety-related parameters
    Safety integrity level:SIL3 (IEC 61508)
    Category:Category 4 (EN ISO 13849)
    Stop category:0, 1 (EN 60204)
    Performance level:PL e (EN ISO 13849)
    PFHd:2.5 * 1E-09
    6.0 * 1E-09
    TM (mission time):20 a



    *изображение на сайте может отличаться от реального
    Нет отзывов об этом товаре.

    Написать отзыв о Flexi Classic Expansion unit Sick UE410-XU3T50 (6032471)

    Ваше Имя:


    Ваш отзыв:

    Оценка: Плохо           Хорошо

    Введите код, указанный на картинке: