Applications |
| Type of switching amplifier: | Safety relay | |
| Emergency stop pushbuttons: | Yes | |
| Safety switches: | Yes | |
| Safety Switch with mechanical lock: | - | |
| Two-hand control systems: | - | |
| Pressure sensitive mats: | - | |
| Opto-electronic protective devices: | - | |
| Opto-electronic protective devices without RES/EDM: | - | |
| Opto-electronic protective devices with RES/EDM: | - | |
| System part: | Safety relays | |
Functions |
| Input circuit: | Single- or dual-channel | |
| Cross-circuit detection: | Yes | |
| Reset/restart: | Manual / automatic / configurable | |
| External device monitoring: | Yes | |
| Synchronous time monitoring: | Yes | |
Technical data |
| Category: | category 4 (EN 954-1) | |
| Stop category: | 0, EN 60204 | |
| Width: | 90 mm | |
| Contact type: | Positively driven | |
| Number of enable current contacts: | 6 | |
| Number of signalling current contacts: | 4 | |
| Operating voltage AC: | 230 V AC | |
| Maximum power consumption AC: | 4.5 VA | |
| Maximum power consumption DC: | 4.2 W | |
| Type of output: | Relay contacts | |
| Rated operating current (voltage): | 3 A (230 V AC) 3600 switching cycles/h 6 A (24 V DC) 360 switching cycles/h 2 A (24 V DC) 3600 switching cycles/h | |
| Maximum switching current: | 6 A | |
| Maximum total current: | 24 A | |
| Mechanical life (relay contacts): | 1*1E 07 switching cycles | |
| Electrical life (relay contacts): | 1*1E 05 switching cycles, dependent upon loading, details see operating instructions | |
| Enclosure rating: | IP 20 | |
| Ambient operating temperature from ... to: | -25 °C ... 55 °C | |
| Connection type: | Screw-type terminals | |
*изображение на сайте может отличаться от реального