Applications |
| Access protection (vertical): | Yes | |
Technical Data-Sender |
| Typical range: | 0 m ... 25 m | |
| Maximum scanning range: | 0 m ... 35 m | |
| Number of beams: | 1 | |
| Light spot diameter (distance): | 200 mm (10 m) | |
| Aperture angle/receiving angle: | according to type 2 (IEC 61496-2) | |
| Light sender/type of light: | LED / visible red light | |
| Wave length: | 660 nm | |
| Average service life (TA): | 100,000 h (25 °C) | |
| Protection class: | II | |
| Enclosure rating: | IP 67 | |
| Type: | Type 2 (EN 61496) 1) | |
| Safety integrity level: | SIL1 (IEC 61508) SILCL1 (IEC 62061) 2) | |
| Category: | category 2 (EN ISO 13849) 3) | |
| Test rate (external test): | 100 /s (EN ISO 13849) 4) | |
| Maximum demand rate: | 60 /min (EN ISO 13849) 5) | |
| Performance level: | PL c (EN ISO 13849) 6) | |
| PFHd: | 1.0 * 1E-06 7) | |
| TM (mission time): | 20 a | |
| Supply voltage typical, from, to: | 24 V DC, 16.8 V DC, 28.8 V DC 8) | |
| Maximum power consumption: | ≤- 35 mA | |
| Diagnostic display: | LED | |
| Design: | Rectangular | |
| Dimensions (W x H x D): | 80.6 mm x 24.6 mm x 54 mm | |
| Connection type: | plug M12 x 4 | |
| Housing material: | ABS | |
| Ambient operating temperature from ... to: | -40 °C ... 60 °C | |
| Storage temperature from ... to: | -40 °C ... 75 °C | |
| Weight: | 100 g | |
Technical Data-Receiver |
| Typical range: | 0 m ... 25 m | |
| Maximum scanning range: | 0 m ... 35 m | |
| Number of beams: | 1 | |
| Light spot diameter (distance): | 200 mm (10 m) | |
| Aperture angle/receiving angle: | according to type 2 (IEC 61496-2) | |
| Protection class: | II | |
| Enclosure rating: | IP 67 | |
| Type: | Type 2 (EN 61496) 1) | |
| Safety integrity level: | SIL1 (IEC 61508) SILCL1 (IEC 62061) 2) | |
| Category: | category 2 (EN ISO 13849) 3) | |
| Test rate (external test): | 100 /s (EN ISO 13849) 4) | |
| Maximum demand rate: | 60 /min (EN ISO 13849) 5) | |
| Performance level: | PL c (EN ISO 13849) 6) | |
| PFHd: | 1.0 * 1E-06 7) | |
| TM (mission time): | 20 a | |
| Supply voltage typical, from, to: | 24 V DC, 16.8 V DC, 28.8 V DC 8) | |
| Switching outputs: | PNP, Q and Q not 9) | |
| Maximum switching sequence: | 1,000 Hz | |
| Maximum switching current: | 100 mA | |
| Maximum power consumption: | ≤- 25 mA | |
| Diagnostic display: | LED | |
| Design: | Rectangular | |
| Dimensions (W x H x D): | 80.6 mm x 24.6 mm x 54 mm | |
| Connection type: | plug M12 x 4 | |
| Housing material: | ABS | |
| Ambient operating temperature from ... to: | -40 °C ... 60 °C | |
| Storage temperature from ... to: | -40 °C ... 75 °C | |
| Weight: | 100 g | |
*изображение на сайте может отличаться от реального